CorrosionRateLab
Menu

Class 2 cap controls the interval

A line measured 10.6 mm in 2020 and 10.4 mm in 2025. It entered service 14 years earlier at 10.8 mm.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0.04 mm/yr
Wall margin
4.1 mm
Remaining life
102.5 yr
UT interval
10 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20112025YearCURRENT WALL10.4 mmRETIREMENT6.3 mmINSPECTION10 yr
Thickness above retirement

Confirm the governing rates, inspection method, service class and current code before setting a due date.

Usable fraction of current wall

Calculation details

Short-term thinning rate
0.04 mm/yr
Long-term thinning rate
0.03 mm/yr
Years between UT readings
5 yr
Governing thinning rate
0.04 mm/yr
Half-life before cap
51.25 yr
Screened inspection interval
10 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 10.4 − 6.3 = 4.1 mm.
  2. Short-term loss rate is 0.04 mm/yr and long-term loss rate is 0.02857 mm/yr.
  3. Remaining life is 102.5 yr. Half-life is 51.25 yr, giving a screened interval of 10 yr.

Half-life exceeds the ten-year screening cap. Confirm whether the actual service or inspection type imposes a shorter limit.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.