Long-term UT rate governs

A spool measured 8.5 mm in 2022 and 8.3 mm in 2025. It entered service 12 years earlier at 11.7 mm.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0.28 mm/yr
Wall margin
2 mm
Remaining life
7.06 yr
UT interval
3.53 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20132025YearCURRENT WALL8.3 mmRETIREMENT6.3 mmINSPECTION3.53 yr
Thickness above retirement

Confirm the governing rates, inspection method, service class and current code before setting a due date.

Usable fraction of current wall

Calculation details

Short-term thinning rate
0.07 mm/yr
Long-term thinning rate
0.28 mm/yr
Years between UT readings
3 yr
Governing thinning rate
0.28 mm/yr
Half-life before cap
3.53 yr
Screened inspection interval
3.53 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 8.3 − 6.3 = 2 mm.
  2. Short-term loss rate is 0.06667 mm/yr and long-term loss rate is 0.28333 mm/yr.
  3. Remaining life is 7.05882 yr. Half-life is 3.52941 yr, giving a screened interval of 3.52941 yr.

The recent trend is flatter than the full history. Retain the larger measured long-term loss rate until the mechanism is understood.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule

    Remaining life = allowance ÷ governing rate. The screening interval is the smaller of half the remaining life and the selected cap. A zero measured rate produces a cap-only interval and no finite life estimate.