CorrosionRateLab
Menu

Retirement check without installed thickness

A spool has comparable 2020 and 2025 UT readings, but its installed thickness and commissioning date are unavailable.

Inputs

SI units

Use comparable readings from the same location. For a short-term-only calculation, leave installed thickness and years in service blank.

mm
mm
mm
mm
yr
yr
Governing rate
0.26 mm/yr
Wall margin
2 mm
Remaining life
7.69 yr
UT interval
3.85 yr

UT thickness history

Schematic
UT thickness history (schematic, not to scale)Measured UTRetirement limit20202025YearCURRENT WALL8.3 mmRETIREMENT6.3 mmINSPECTION3.85 yr
Thickness above retirement

Confirm the governing rates, inspection method, service class and current code before setting a due date.

Usable fraction of current wall

Calculation details

Short-term thinning rate
0.26 mm/yr
Long-term thinning rate
—
Years between UT readings
5 yr
Governing thinning rate
0.26 mm/yr
Half-life before cap
3.85 yr
Screened inspection interval
3.85 yr

Worked calculation

Starting values · SI
  1. Current wall minus retirement wall is 8.3 − 6.3 = 2 mm.
  2. Short-term loss rate is 0.26 mm/yr.
  3. Remaining life is 7.69231 yr. Half-life is 3.84615 yr, giving a screened interval of 3.84615 yr.

Use the available short-term trend. Add the original record if its location and instrument basis can be verified.

Method and limits

  1. Compare short and long histories

    Short-term rate = (previous UT − current UT) ÷ elapsed years. Long-term rate = (installed thickness − current UT) ÷ years in service when both inputs are given. Use the larger credible rate.

  2. Measure the retirement margin

    Allowance = current thickness − retirement thickness. At or below retirement, the screen returns zero life and zero interval. Confirm a rising thickness trend before assigning a rate.

  3. Apply the half-life rule