Short GPON branch below minimum loss

A B+ ODN with only a 1:2 split and a short drop.

Inputs

Pick an optics class to fill in typical planning values, then check the actual OLT and ONU specifications. For tap stages, enter the percentage on the path being tested.

Optics and cable
km
km
dB
Splitter stage 1
dB
Splitter stage 2
Splitter stage 3
Plant and class limits
dB
dB
dB
dB
km
Downstream · OLT to ONU
dBm
dBm
dBm
dBm
dB/km
Upstream · ONU to OLT
dBm
dBm
dBm
dBm
dB/km
LIVE ANATOMY

OLT to ONU branch budget

OLT to ONU branch budgetSPLIT LOSS3.41dBDOWN MARGIN21.715dBUP MARGIN21.685dBMAX REACH—Feeder 0.1 kmDrop 0.2 kmOLTONU1:23.41 dBBypassBypassTX low1.5 dBmRX low-2.79 dBmLIMITING POWER MARGIN0 dB28 dB limit21.68 dB left
Minimum loss unmetThis path needs additional loss for the class floor or receiver overload ceiling. Recheck both directions with attenuation.

With the current passive losses and route cap, no span length satisfies both ends of the unattenuated loss window.

Branch limits

Cascaded splitter loss
3.41 dB
Fixed loss before fiber
4.21 dB
Feeder + drop
0.3 km
Maximum usable reach
No feasible span
Minimum span without added loss
35.159 km
Added attenuation to satisfy loss floors
8.715 dB

Downstream · OLT to ONU

TX-to-sensitivity budget
28.5 dB
Allowed physical loss window
13 to 28 dB
Predicted ODN loss
4.285 dB
Low to high receive power
-2.785 to 0.715 dBm
Margin after reserve
21.715 dB
Space below overload
-8.715 dB

Upstream · ONU to OLT

TX-to-sensitivity budget
28.5 dB
Allowed physical loss window
13 to 28 dB
Predicted ODN loss
4.315 dB
Low to high receive power
-3.815 to 0.685 dBm
Margin after reserve
21.685 dB
Space below overload
-8.685 dB

Selected splitter ports

Stage 1 · 50% port
3.41 dB
Stage 2
Bypassed
Stage 3
Bypassed

What to check

A large top-end budget cannot satisfy the class floor on a branch with very little attenuation.

Open the general pon splitter budget calculator

Formulas and assumptions

Balanced and unbalanced splits

Lstage = −10 log₁₀(port fraction) + excess loss

Use 1/N for an equal 1:N stage or the selected percentage divided by 100 for a tap. Add losses along just the chosen branch.

Low and high received power

RXlow = TXmin − Lpath; RXhigh = TXmax − Lpath

Use separate cable attenuation in each direction. The highest receive power is compared with the overload ceiling.

ODN window and reach

Lmax = min(class max, TXmin − RX sensitivity); Lmin = max(class min, TXmax − RX overload)

Reach in each direction is (Lmax − fixed loss − reserve) / α. The usable reach is the smaller result, capped at the entered route limit and subject to both physical loss floors.

B+ and C+ follow the G.984.2/G.9807.1 class-window convention. N1 and N2 use the G.9807.1 basic wavelength set. C++ is a vendor profile. PX20 uses the EPON planning window. The TX/RX entries are editable presets and the route cap represents an entered equipment limit. Verify wavelength plans, splitters, differential reach and equipment interoperability separately.

Worked examples

Open a scenario and edit any parameter.