XGS-PON N2 across three stages

Try 1:4, 1:8 and 1:4 stages on a 23 km planned route.

Inputs

Pick an optics class to fill in typical planning values, then check the actual OLT and ONU specifications. For tap stages, enter the percentage on the path being tested.

Optics and cable
km
km
dB
Splitter stage 1
dB
Splitter stage 2
dB
Splitter stage 3
dB
Plant and class limits
dB
dB
dB
dB
km
Downstream · OLT to ONU
dBm
dBm
dBm
dBm
dB/km
Upstream · ONU to OLT
dBm
dBm
dBm
dBm
dB/km
LIVE ANATOMY

OLT to ONU branch budget

OLT to ONU branch budgetSPLIT LOSS24.072dBDOWN MARGIN-3.972dBUP MARGIN-5.812dBMAX REACH7.705kmFeeder 20 kmDrop 3 kmOLTONU1:47.02 dB1:810.03 dB1:47.02 dBTX low4 dBmRX low-28.97 dBmLIMITING POWER MARGIN0 dB31 dB limit-5.81 dB left
Path exceeds limitCheck both directional margins and the entered maximum route length.

Branch limits

Cascaded splitter loss
24.072 dB
Fixed loss before fiber
26.072 dB
Feeder + drop
23 km
Maximum usable reach
7.705 km
Minimum span without added loss
0 km
Added attenuation to satisfy loss floors
0 dB

Downstream · OLT to ONU

TX-to-sensitivity budget
32 dB
Allowed physical loss window
16 to 31 dB
Predicted ODN loss
32.972 dB
Low to high receive power
-28.972 to -25.972 dBm
Margin after reserve
-3.972 dB
Space below overload
16.972 dB

Upstream · ONU to OLT

TX-to-sensitivity budget
32 dB
Allowed physical loss window
16 to 31 dB
Predicted ODN loss
34.812 dB
Low to high receive power
-30.812 to -25.812 dBm
Margin after reserve
-5.812 dB
Space below overload
18.812 dB

Selected splitter ports

Stage 1 · 25% port
7.021 dB
Stage 2 · 12.5% port
10.031 dB
Stage 3 · 25% port
7.021 dB

What to check

The reach cap applies even if a different split or a better cable improves the loss margin.

Open the general pon splitter budget calculator

Formulas and assumptions

Balanced and unbalanced splits

Lstage = −10 log₁₀(port fraction) + excess loss

Use 1/N for an equal 1:N stage or the selected percentage divided by 100 for a tap. Add losses along just the chosen branch.

Low and high received power

RXlow = TXmin − Lpath; RXhigh = TXmax − Lpath

Use separate cable attenuation in each direction. The highest receive power is compared with the overload ceiling.

ODN window and reach

Lmax = min(class max, TXmin − RX sensitivity); Lmin = max(class min, TXmax − RX overload)

Reach in each direction is (Lmax − fixed loss − reserve) / α. The usable reach is the smaller result, capped at the entered route limit and subject to both physical loss floors.

B+ and C+ follow the G.984.2/G.9807.1 class-window convention. N1 and N2 use the G.9807.1 basic wavelength set. C++ is a vendor profile. PX20 uses the EPON planning window. The TX/RX entries are editable presets and the route cap represents an entered equipment limit. Verify wavelength plans, splitters, differential reach and equipment interoperability separately.

Worked examples