Reach in each direction is (Lmax − fixed loss − reserve) / α. The usable reach is the smaller result, capped at the entered route limit and subject to both physical loss floors.
B+ and C+ follow the G.984.2/G.9807.1 class-window convention. N1 and N2 use the G.9807.1 basic wavelength set. C++ is a vendor profile. PX20 uses the EPON planning window. The TX/RX entries are editable presets and the route cap represents an entered equipment limit. Verify wavelength plans, splitters, differential reach and equipment interoperability separately.
Pass. Both directions meet the ODN loss window and entered route cap.
Inputs
PON optics class
B+ · GPON
Feeder length
8 km
Drop length
1 km
Design reserve
2 dB
Port ratio
1:32
Excess loss
1.1 dB
Port ratio
Bypass
Port ratio
Bypass
Mated connector pairs
4
Loss per pair
0.4 dB
Splices
4
Loss per splice
0.1 dB
ODN minimum loss
13 dB
ODN maximum loss
28 dB
Maximum route length
20 km
OLT minimum launch
1.5 dBm
OLT maximum launch
5 dBm
ONU sensitivity
-27 dBm
ONU overload
-8 dBm
Downstream attenuation
0.25 dB/km
ONU minimum launch
0.5 dBm
ONU maximum launch
5 dBm
OLT sensitivity
-28 dBm
OLT overload
-8 dBm
Upstream attenuation
0.35 dB/km
Results
Cascaded splitter loss
16.151 dB
Fixed loss before fiber
18.151 dB
Feeder + drop
9 km
Maximum usable reach
20 km
Minimum span without added loss
0 km
Added attenuation to satisfy loss floors
0 dB
TX-to-sensitivity budget
28.5 dB
Allowed physical loss window
13 to 28 dB
Predicted ODN loss
20.401 dB
Low to high receive power
-18.901 to -15.401 dBm
Margin after reserve
5.599 dB
Space below overload
7.401 dB
TX-to-sensitivity budget
28.5 dB
Allowed physical loss window
13 to 28 dB
Predicted ODN loss
21.301 dB
Low to high receive power
-20.801 to -16.301 dBm
Margin after reserve
4.699 dB
Space below overload
8.301 dB
Stage 1 · 3.125% port
16.151 dB
Stage 2
Bypassed
Stage 3
Bypassed
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.