Reach in each direction is (Lmax − fixed loss − reserve) / α. The usable reach is the smaller result, capped at the entered route limit and subject to both physical loss floors.
B+ and C+ follow the G.984.2/G.9807.1 class-window convention. N1 and N2 use the G.9807.1 basic wavelength set. C++ is a vendor profile. PX20 uses the EPON planning window. The TX/RX entries are editable presets and the route cap represents an entered equipment limit. Verify wavelength plans, splitters, differential reach and equipment interoperability separately.
Pass. Both directions meet the ODN loss window and entered route cap.
Inputs
PON optics class
N1 · XGS-PON
Feeder length
10 km
Drop length
0.6 km
Design reserve
2 dB
Port ratio
Unbalanced tap
Power into chosen port
15 %
Excess loss
0.6 dB
Port ratio
1:8
Excess loss
1 dB
Port ratio
Bypass
Mated connector pairs
3
Loss per pair
0.4 dB
Splices
4
Loss per splice
0.1 dB
ODN minimum loss
14 dB
ODN maximum loss
29 dB
Maximum route length
20 km
OLT minimum launch
2 dBm
OLT maximum launch
5 dBm
ONU sensitivity
-28 dBm
ONU overload
-9 dBm
Downstream attenuation
0.3 dB/km
ONU minimum launch
4 dBm
ONU maximum launch
9 dBm
OLT sensitivity
-26 dBm
OLT overload
-5 dBm
Upstream attenuation
0.38 dB/km
Results
Cascaded splitter loss
18.87 dB
Fixed loss before fiber
20.47 dB
Feeder + drop
10.6 km
Maximum usable reach
17.184 km
Minimum span without added loss
0 km
Added attenuation to satisfy loss floors
0 dB
TX-to-sensitivity budget
30 dB
Allowed physical loss window
14 to 29 dB
Predicted ODN loss
23.65 dB
Low to high receive power
-21.65 to -18.65 dBm
Margin after reserve
3.35 dB
Space below overload
9.65 dB
TX-to-sensitivity budget
30 dB
Allowed physical loss window
14 to 29 dB
Predicted ODN loss
24.498 dB
Low to high receive power
-20.498 to -15.498 dBm
Margin after reserve
2.502 dB
Space below overload
10.498 dB
Stage 1 · 15% port
8.839 dB
Stage 2 · 12.5% port
10.031 dB
Stage 3
Bypassed
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.