Reach in each direction is (Lmax − fixed loss − reserve) / α. The usable reach is the smaller result, capped at the entered route limit and subject to both physical loss floors.
B+ and C+ follow the G.984.2/G.9807.1 class-window convention. N1 and N2 use the G.9807.1 basic wavelength set. C++ is a vendor profile. PX20 uses the EPON planning window. The TX/RX entries are editable presets and the route cap represents an entered equipment limit. Verify wavelength plans, splitters, differential reach and equipment interoperability separately.
Path exceeds limit. Check both directional margins and the entered maximum route length.
Inputs
PON optics class
N2 · XGS-PON
Feeder length
20 km
Drop length
3 km
Design reserve
2 dB
Port ratio
1:4
Excess loss
1 dB
Port ratio
1:8
Excess loss
1 dB
Port ratio
1:4
Excess loss
1 dB
Mated connector pairs
4
Loss per pair
0.4 dB
Splices
4
Loss per splice
0.1 dB
ODN minimum loss
16 dB
ODN maximum loss
31 dB
Maximum route length
20 km
OLT minimum launch
4 dBm
OLT maximum launch
7 dBm
ONU sensitivity
-28 dBm
ONU overload
-9 dBm
Downstream attenuation
0.3 dB/km
ONU minimum launch
4 dBm
ONU maximum launch
9 dBm
OLT sensitivity
-28 dBm
OLT overload
-7 dBm
Upstream attenuation
0.38 dB/km
Results
Cascaded splitter loss
24.072 dB
Fixed loss before fiber
26.072 dB
Feeder + drop
23 km
Maximum usable reach
7.705 km
Minimum span without added loss
0 km
Added attenuation to satisfy loss floors
0 dB
TX-to-sensitivity budget
32 dB
Allowed physical loss window
16 to 31 dB
Predicted ODN loss
32.972 dB
Low to high receive power
-28.972 to -25.972 dBm
Margin after reserve
-3.972 dB
Space below overload
16.972 dB
TX-to-sensitivity budget
32 dB
Allowed physical loss window
16 to 31 dB
Predicted ODN loss
34.812 dB
Low to high receive power
-30.812 to -25.812 dBm
Margin after reserve
-5.812 dB
Space below overload
18.812 dB
Stage 1 · 25% port
7.021 dB
Stage 2 · 12.5% port
10.031 dB
Stage 3 · 25% port
7.021 dB
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.