GasCompressLab

API 617 · GPSA §13

Carbon dioxide recycle loop

A dry CO₂ recycle loop returns compressed gas at 3,400 kPa(a) from an 1,800 kPa(a) suction.

What to check

The molecular weight and entered Z affect head per kilogram. Confirm phase behavior outside this constant-property screen.

Operating readout

Edit inputs ↓
Poly. head
35.19kJ/kg
Brake power
206.79kW
Discharge T
106.79°C
Pressure ratio
1.889×
Within entered thermal envelopeDischarge gas is below the entered casing limit.
Centrifugal stage and pressure–enthalpy pathCENTRIFUGAL STAGEkPa(a)P₁ 1800P₂ 340046 °C107 °CPRESSURE / ENTHALPYΔh · kJ/kg34001800042.9 kJ/kgTHERMAL MARGIN68.2 K
The solid curve tracks the estimated gas enthalpy rise. The dashed curve shows the isentropic comparison.
Calculated details
Isentropic head
34.63kJ/kg
Equivalent isentropic efficiency
80.69%
Power to gas
202.65kW
Exponent ratio (n − 1) / n
0.27415
Gas temperature rise
60.79K
Casing temperature margin
68.21K
Mass flow used
17,000kg/h

Operating inputs

Compression duty
kPa(a)
kPa(a)
°C
°C
Enter the service limit from the project or vendor.
kg/h
Gas and efficiency
Preset properties are starting values.
kg/kmol
%
%

Calculation basis

Head

Set a = (k − 1)/(kηₚ). Hₚ = ZRT₁[(P₂/P₁)ᵃ − 1]/(MW·a). Compute Hₛ with a = (k − 1)/k.

Temperature and shaft work

T₂ = T₁(P₂/P₁)ᵃ. Gas power is ṁHₚ/ηₚ. Divide by mechanical efficiency to get brake power. Equivalent isentropic efficiency is Hₛηₚ/Hₚ.

Related worked examples