API 617 · GPSA §13
Ethane export boost
Ethane is boosted from 1,400 to 2,050 kPa(a) for transfer at a 24 t/h mass flow.
A small temperature rise may still correspond to substantial shaft work when throughput is high.
Operating readout
Edit inputs ↓- Poly. head
- 31.41kJ/kg
- Brake power
- 279.63kW
- Discharge T
- 67.67°C
- Pressure ratio
- 1.464×
Calculated details
- Isentropic head
- 31.12kJ/kg
- Equivalent isentropic efficiency
- 77.3%
- Power to gas
- 268.44kW
- Exponent ratio (n − 1) / n
- 0.21368
- Gas temperature rise
- 26.67K
- Casing temperature margin
- 107.33K
- Mass flow used
- 24,000kg/h
Operating inputs
Operating inputs
- Suction pressure P₁
- 1,400kPa(a)
- Discharge pressure P₂
- 2,050kPa(a)
- Suction temperature T₁
- 41°C
- Casing temperature limit
- 175°C
- Flow basis
- Mass flow
- Gas flow
- 24,000kg/h
- Gas preset
- Ethane C₂H₆
- Molecular weight
- 30.07kg/kmol
- Specific heat ratio k
- 1.2
- Average compressibility Z
- 0.91
- Polytropic efficiency
- 78%
- Mechanical efficiency
- 96%
Calculated details
- Isentropic head
- 31.12kJ/kg
- Equivalent isentropic efficiency
- 77.3%
- Power to gas
- 268.44kW
- Exponent ratio (n − 1) / n
- 0.21368
- Gas temperature rise
- 26.67K
- Casing temperature margin
- 107.33K
- Mass flow used
- 24,000kg/h
Use absolute pressure and absolute temperature in the equations. Constant k, average Z, and an entered casing limit give a preliminary estimate. API 617 equipment selection and ASME PTC 10 or ISO 5389 performance verification require the applicable project specification and vendor data. Actual suction flow uses the entered average Z as suction Z.
Calculation basis
Head
Set a = (k − 1)/(kηₚ). Hₚ = ZRT₁[(P₂/P₁)ᵃ − 1]/(MW·a). Compute Hₛ with a = (k − 1)/k.
Temperature and shaft work
T₂ = T₁(P₂/P₁)ᵃ. Gas power is ṁHₚ/ηₚ. Divide by mechanical efficiency to get brake power. Equivalent isentropic efficiency is Hₛηₚ/Hₚ.
Related worked examples
-
Gathering train gas booster →
A gathering booster lifts dry gas from 360 kPa(a) to a 1,080 kPa(a) header at 7.8 t/h.
-
Nitrogen utility header make-up →
A plant nitrogen compressor raises pressure from 115 to 560 kPa(a) using a normal-volume flow basis.
-
Carbon dioxide recycle loop →
A dry CO₂ recycle loop returns compressed gas at 3,400 kPa(a) from an 1,800 kPa(a) suction.
-
Hydrogen purification recycle →
A dry hydrogen compressor operates on a 2.0 pressure ratio and a 2,600 kg/h mass flow.
-
Dry plant-air booster →
A dry-air service uses 2,900 actual m³/h at suction as the basis for shaft power.
-
Propane vapor recompression →