Fan similarity · Surge margin

Process demand below surge

A sudden reduction in process demand takes the unrecycled operating point below the estimated surge limit.

What to check

The chart marks the demand left of the surge boundary. Recycle flow is the difference to the margin target.

Operating readout

Edit inputs ↓
Scaled flow
13,088.14m³/h
Shaft power
250.1kW
Surge margin
-15.61%
Recycle flow
2,162.71m³/h
Demand at or below surgeThe unrecycled demand crosses the scaled surge point.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 11800N₂ 10800rpm23800016400 m³/hFLOW / CONTROL LINE77.8%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
1,424.07m
Equivalent pressure rise
55.72kPa
Dimensionless specific speed
1.67861
Scaled surge point
8,786.44m³/h
Minimum stable flow at target margin
9,762.71m³/h
Demand plus required recycle
9,762.71m³/h
Turn-down, nominal / minimum
1.341×
Reference shaft power
343.37kW
Speed ratio N₂ / N₁
0.9153×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.