GasCompressLab

Fan similarity · Surge margin

Narrow compressor turn-down range

A compressor with a high surge flow is evaluated against a 16% margin target.

What to check

The control line can sit beyond the nominal scaled point. Turn-down below one flags the target as infeasible on the entered basis.

Operating readout

Edit inputs ↓
Scaled flow
9,036.89m³/h
Shaft power
133.67kW
Surge margin
6.12%
Recycle flow
1,023.76m³/h
Target exceeds scaled design flowThe requested margin requires more than the scaled design flow.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 10300N₂ 8950rpm20400012000 m³/hFLOW / CONTROL LINE89.5%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
1,102.36m
Equivalent pressure rise
43.13kPa
Dimensionless specific speed
1.40064
Scaled surge point
8,167.96m³/h
Minimum stable flow at target margin
9,723.76m³/h
Demand plus required recycle
9,723.76m³/h
Turn-down, nominal / minimum
0.929×
Reference shaft power
214.47kW
Speed ratio N₂ / N₁
0.8689×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.