GasCompressLab

Fan similarity · Surge margin

Low-speed operation with no recycle

A slower speed point maintains demand above the 10% control line at a slightly higher gas density.

What to check

Density changes power and pressure rise. The head scaling still follows speed squared.

Operating readout

Edit inputs ↓
Scaled flow
6,915.46m³/h
Shaft power
98.33kW
Surge margin
29.13%
Recycle flow
0m³/h
Within modeled surge envelopeProcess demand meets the selected margin at the new speed.
Scaled head–flow curves and surge control lineHEAD / FLOW MAPmN₁ 9700N₂ 7800rpm1950009890 m³/hFLOW / CONTROL LINE127%
Speed-line shapes are illustrative. The marked nominal flow and head follow the entered affinity laws. The demand marker is projected onto the new-speed curve.
Calculated details
Scaled head
898.79m
Equivalent pressure rise
41.46kPa
Dimensionless specific speed
1.24451
Scaled surge point
4,181.44m³/h
Minimum stable flow at target margin
4,646.05m³/h
Demand plus required recycle
5,900m³/h
Turn-down, nominal / minimum
1.488×
Reference shaft power
168.85kW
Speed ratio N₂ / N₁
0.8041×

Operating inputs

Reference point
rpm
m³/h
m
Head is expressed as a length. Use specific energy divided by g.
%
m³/h
kg/m³
New operating point
rpm
×
Enter the ratio as a multiplier.
m³/h
%

Calculation basis

Scale the point

At constant geometry and efficiency, flow scales with speed, head with speed squared, and power with speed cubed times density ratio. Dimensionless specific speed is ω√Q/(gH)^(3/4).

Place the control line

Scale the surge flow linearly with speed. Margin is (process demand − surge flow)/process demand. The target flow is Q_surge/(1 − target margin). Recycle supplies the positive shortfall.

Related worked examples