GasCompressLab

API 618 · GPSA §13

Multistage reciprocating compression

Balance up to four stage pressure ratios with intercooler losses and check temperature, delivered capacity, and gas rod load.

Operating readout

Edit inputs ↓
Stage ratio
2.131×
Peak temp
103.55°C
Total power
303.08kW
Cylinder VE
91.23%
Stages within screening limitsTemperature and static gas rod load are within the entered screening basis.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 1746CYL 21530CYL 33200DISCHARGE TEMPERATURE°C · r 2.1313532STG 1STG 2STG 3CYLINDER DELIVERY91.2% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
44.49kN
Rod load utilization
35.59%
Total intercooler duty
192.09kW
Single-stage gas power
346.7kW
Power reduction vs single-stage
12.58%
Service temperature screen
135°C
Temperature margin
31.45K
Hydrogen vendor shutdown example
—
Mass flow used
3,131.98kg/h

Stage schedule

  1. Stage 1

    Suction
    350kPa(a)
    Discharge
    745.83kPa(a)
    Outlet temp
    96.29°C
    Gas power
    99.72kW
    Cooler duty
    90.41kW
    Gas rod load
    10.3kN
  2. Stage 2

    Suction
    717.83kPa(a)
    Discharge
    1,529.67kPa(a)
    Outlet temp
    103.55°C
    Gas power
    101.68kW
    Cooler duty
    101.68kW
    Gas rod load
    21.22kN
  3. Stage 3

    Suction
    1,501.67kPa(a)
    Discharge
    3,200kPa(a)
    Outlet temp
    103.55°C
    Gas power
    101.68kW
    Cooler duty
    0kW
    Gas rod load
    44.49kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
°C
kPa
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.

Worked examples