GasCompressLab

API 618 · GPSA §13

Four-stage tube-trailer fill

A hypothetical four-stage gas fill case puts 120 kPa(a) gas into a 6,000 kPa(a) header.

What to check

Lower per-stage pressure ratios reduce temperature rise. The stage load table shows where a common bore can become limiting.

Operating readout

Edit inputs ↓
Stage ratio
2.698×
Peak temp
126.37°C
Total power
121.26kW
Cylinder VE
87.26%
Interstage temperature cautionA cylinder approaches the service temperature screen.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 1324CYL 2841CYL 32240CYL 46000DISCHARGE TEMPERATURE°C · r 2.713532STG 1STG 2STG 3STG 4CYLINDER DELIVERY87.3% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
47.64kN
Rod load utilization
45.38%
Total intercooler duty
88.73kW
Single-stage gas power
168.48kW
Power reduction vs single-stage
28.03%
Service temperature screen
135°C
Temperature margin
8.63K
Hydrogen vendor shutdown example
—
Mass flow used
695.99kg/h

Stage schedule

  1. Stage 1

    Suction
    120kPa(a)
    Discharge
    323.72kPa(a)
    Outlet temp
    118.67°C
    Gas power
    29.87kW
    Cooler duty
    27.81kW
    Gas rod load
    2.51kN
  2. Stage 2

    Suction
    311.72kPa(a)
    Discharge
    840.92kPa(a)
    Outlet temp
    126.37°C
    Gas power
    30.46kW
    Cooler duty
    30.46kW
    Gas rod load
    6.62kN
  3. Stage 3

    Suction
    828.92kPa(a)
    Discharge
    2,236.14kPa(a)
    Outlet temp
    126.37°C
    Gas power
    30.46kW
    Cooler duty
    30.46kW
    Gas rod load
    17.72kN
  4. Stage 4

    Suction
    2,224.14kPa(a)
    Discharge
    6,000kPa(a)
    Outlet temp
    126.37°C
    Gas power
    30.46kW
    Cooler duty
    0kW
    Gas rod load
    47.64kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
°C
kPa
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.