GasCompressLab

API 618 · GPSA §13

Hydrogen-rich compressor staging

Three stages with a hydrogen-rich gas screen boost compressor inlet gas to 4,400 kPa(a).

What to check

Compare the sixth-edition 120 °C prediction screen against the alternate 135 °C screening basis and vendor shutdown benchmark.

Operating readout

Edit inputs ↓
Stage ratio
1.978×
Peak temp
118.76°C
Total power
193.56kW
Cylinder VE
93.03%
Interstage temperature cautionA cylinder approaches the service temperature screen.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 11170CYL 22250CYL 34400DISCHARGE TEMPERATURE°C · r 1.9812032STG 1STG 2STG 3CYLINDER DELIVERY93% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
57.28kN
Rod load utilization
45.83%
Total intercooler duty
118.8kW
Single-stage gas power
226.23kW
Power reduction vs single-stage
14.44%
Service temperature screen
120°C
Temperature margin
1.24K
Hydrogen vendor shutdown example
148.89°C
Mass flow used
430.98kg/h

Stage schedule

  1. Stage 1

    Suction
    590kPa(a)
    Discharge
    1,166.93kPa(a)
    Outlet temp
    105.13°C
    Gas power
    63.01kW
    Cooler duty
    53.53kW
    Gas rod load
    15.12kN
  2. Stage 2

    Suction
    1,138.93kPa(a)
    Discharge
    2,252.64kPa(a)
    Outlet temp
    118.76°C
    Gas power
    65.28kW
    Cooler duty
    65.28kW
    Gas rod load
    29.28kN
  3. Stage 3

    Suction
    2,224.64kPa(a)
    Discharge
    4,400kPa(a)
    Outlet temp
    118.76°C
    Gas power
    65.28kW
    Cooler duty
    0kW
    Gas rod load
    57.28kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
°C
kPa
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.