Single-stage vapor recovery

A single cylinder handles a 900 Nm³/h vapor-recovery duty from 170 to 455 kPa(a).

What to check

There is no intercooler in the model. The single-stage comparison is exactly the same duty.

Operating readout

Edit inputs ↓
Stage ratio
2.676×
Peak temp
111.49°C
Total power
32.76kW
Cylinder VE
79.39%
Stages within screening limitsTemperature and static gas rod load are within the entered screening basis.
Cylinder train and stage discharge temperaturesCYLINDERS & INTERCOOLERSkPa(a)CYL 1455DISCHARGE TEMPERATURE°C · r 2.6813527STG 1CYLINDER DELIVERY79.4% VE
Each cylinder uses the solved common ratio. Intercooler symbols mark where pressure is lost and temperature is reset.
Calculated details
Peak static gas rod load
7.31kN
Rod load utilization
5.85%
Total intercooler duty
0kW
Single-stage gas power
32.76kW
Power reduction vs single-stage
0%
Service temperature screen
135°C
Temperature margin
23.51K
Hydrogen vendor shutdown example
—
Mass flow used
782.99kg/h

Stage schedule

  1. Stage 1

    Suction
    170kPa(a)
    Discharge
    455kPa(a)
    Outlet temp
    111.49°C
    Gas power
    32.76kW
    Cooler duty
    0kW
    Gas rod load
    7.31kN

Operating inputs

Stage duty
kPa(a)
kPa(a)
°C
Nm³/h
Gas and cylinder
kg/kmol
%
%
mm
mm
kN

Calculation basis

Solve the pressure ladder

For each cylinder use P_out = rP_in. Subtract the entered pressure loss before the next stage. Solve r until the final discharge matches the target. Without losses r = (P_final/P₁)^(1/N).

Cylinder load and cooling

Clearance-only ηᵥ = 1 − c(r^(1/k) − 1). Use the full bore and rod-side annulus to estimate the maximum static differential gas load. Intercooler duty uses positive sensible heat removal only.