Curtain-wall mullion deflection calculator

Check bending and deflection of an aluminum extrusion with a 45-degree glass tributary load.

L/175 · L/240 · 19 mm cap

Inputs

Span and loading
m
m
kPa
Aluminum section
cm⁴
cm³
GPa
MPa

0 uses the illustrative alloy allowance.

Screening result

Mullion deflection or bending stress exceeds the selected limit.

Fail
Deflection
26.24mm
Service limit
21.71mm
Bend stress
94.3MPa
Bending use
85.7%
Curtain-wall tributary loading and beam responseCurtain-wall mullion. Deflection 26.24 mm. Service limit 21.71 mm. Bend stress 94.3 MPa. Bending use 85.7 %.Wind load onto mullionTrapezoidal · span 3.8 mPeak 2.7 kN/mOut-of-plane responseSimply supported spanMδMomentDeflectionGoverning mullion demand0%100% limit200%+

Calculation details

Peak tributary line load
2.7 kN/m
Maximum absolute bending moment
4.62 kN·m
Uncapped L/175
21.714 mm
L/175 with long-span cap
21.714 mm
L/240 reference
15.833 mm
Elastic modulus
69 GPa
Selected bending allowance
110 MPa
Deflection utilization
120.9 %

Formula trace in SI

  1. Tributary wind

    w(x) = q min(B, 2x, 2(L − x))

    Trapezoidal load, peak 2.7 kN/m.

  2. Beam response

    EI y″ = M(x); σ = |M|max / Sx

    Zero displacement at both pins. |M|max = 4.62 kN·m, δmax = 26.243 mm.

  3. Service criterion

    δallow = L/175, capped at 19 mm if L > 4.1 m

    Selected 21.714 mm, deflection use 120.85 %.

  4. Bending criterion

    Utilization = σ / σallow

    94.293 MPa / 110 MPa = 85.72 %.