GlassFacadeLab · Center-of-glass thermal model
High-humidity pool glazing
Worked example · SI
Fail · The room-side glass is below the indoor dew point.
Inputs
- Pane count
- Double pane
- Outer pane
- 6 mm
- Inner pane
- 6 mm
- Unit width
- 1.6 m
- Unit height
- 2.2 m
- Gas fill
- Argon
- Cavity width
- 12 mm
- Outer-facing emissivity ε₁
- 0.05
- Inner-facing emissivity ε₂
- 0.84
- Indoor air temperature
- 28 °C
- Outdoor air temperature
- -18 °C
- Indoor relative humidity
- 70 %
- Spacer Ψ-edge
- Metal edge · 0.08 SI
- Assembly solar transmittance
- 0.48
- Assembly solar absorptance
- 0.28
- Absorbed heat location
- Outer pane
Results
- Glass U-factor
- 1.447 W/(m²·K)
- Glass SHGC
- 0.497
- Glass surface
- 19.4 °C
- Dew margin
- -2.66 K
- Indoor dew point
- 22.015 °C
- Glass plus linear edge U-factor
- 1.62 W/(m²·K)
- Linear spacer transmittance Ψ
- 0.08 W/(m·K)
- Heat flux toward exterior
- 66.57 W/m²
- Cavity 1 gas conductance
- 1.729 W/(m²·K)
- Cavity 1 radiative conductance
- 0.235 W/(m²·K)
Formula trace in SI
Gas and radiation
hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)
Gap 1: 1.371 conductive × Nu 1.261 + 0.235 radiative W/(m²·K).
Center and edge heat flow
Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A
ΣR = 0.691 m²·K/W, edge addition 0.173 W/(m²·K).
Solar gain
SHGC = τsolar + αsolar·Rout/Rtotal
Inward absorbed fraction 6.22 %, SHGC 0.497.
Condensation margin
Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp
Magnus dew point 22.015 °C, surface 19.354 °C, margin -2.661 K.