Narrow krypton triple unit

A shallow historic sash requires narrow cavities in a triple build-up.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
mm
m
m
Exterior cavity
mm
Interior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The center of glass is at least 2 K above the indoor dew point.

Pass
Glass U-factor
0.645W/(m²·K)
Glass SHGC
0.488
Glass surface
17.6°C
Dew margin
6.52K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 0.645 W/(m²·K). Glass SHGC 0.488. Glass surface 17.6 °C. Dew margin 6.52 K.Insulating glass section3 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side-20 °C21 °CGlass profileDew 11.1 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
11.051 °C
Glass plus linear edge U-factor
0.788 W/(m²·K)
Linear spacer transmittance Ψ
0.04 W/(m·K)
Heat flux toward exterior
26.43 W/m²
Cavity 1 gas conductance
1.252 W/(m²·K)
Cavity 1 radiative conductance
0.206 W/(m²·K)
Cavity 2 gas conductance
1.171 W/(m²·K)
Cavity 2 radiative conductance
0.301 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 1.198 conductive × Nu 1.045 + 0.206 radiative W/(m²·K). Gap 2: 1.113 conductive × Nu 1.053 + 0.301 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 1.551 m²·K/W, edge addition 0.143 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 2.77 %, SHGC 0.488.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 11.051 °C, surface 17.568 °C, margin 6.517 K.