Cold-room vision panel

A compact sight panel sees cold air on its exterior side and humid occupied air inside.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
m
m
Exterior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The room-side glass is below the indoor dew point.

Fail
Glass U-factor
1.456W/(m²·K)
Glass SHGC
0.498
Glass surface
9.9°C
Dew margin
-0.98K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 1.456 W/(m²·K). Glass SHGC 0.498. Glass surface 9.9 °C. Dew margin -0.98 K.Insulating glass section2 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side-25 °C18 °CGlass profileDew 10.8 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
10.847 °C
Glass plus linear edge U-factor
1.738 W/(m²·K)
Linear spacer transmittance Ψ
0.04 W/(m·K)
Heat flux toward exterior
62.61 W/m²
Cavity 1 gas conductance
1.766 W/(m²·K)
Cavity 1 radiative conductance
0.214 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 1.233 conductive × Nu 1.433 + 0.214 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 0.687 m²·K/W, edge addition 0.282 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 6.26 %, SHGC 0.498.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 10.847 °C, surface 9.869 °C, margin -0.978 K.