GlassFacadeLab · Center-of-glass thermal model
Clear air-filled storefront IGU
Worked example · SI
Warn · The glass is at the dew point or within 2 K of it.
Inputs
- Pane count
- Double pane
- Outer pane
- 6 mm
- Inner pane
- 6 mm
- Unit width
- 1.35 m
- Unit height
- 2.1 m
- Gas fill
- Air
- Cavity width
- 10 mm
- Outer-facing emissivity ε₁
- 0.84
- Inner-facing emissivity ε₂
- 0.84
- Indoor air temperature
- 20 °C
- Outdoor air temperature
- -8 °C
- Indoor relative humidity
- 46 %
- Spacer Ψ-edge
- Metal edge · 0.08 SI
- Assembly solar transmittance
- 0.68
- Assembly solar absorptance
- 0.21
- Absorbed heat location
- Outer pane
Results
- Glass U-factor
- 2.841 W/(m²·K)
- Glass SHGC
- 0.706
- Glass surface
- 9.7 °C
- Dew margin
- 1.65 K
- Indoor dew point
- 8.021 °C
- Glass plus linear edge U-factor
- 3.036 W/(m²·K)
- Linear spacer transmittance Ψ
- 0.08 W/(m·K)
- Heat flux toward exterior
- 79.56 W/m²
- Cavity 1 gas conductance
- 2.44 W/(m²·K)
- Cavity 1 radiative conductance
- 3.439 W/(m²·K)
Formula trace in SI
Gas and radiation
hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)
Gap 1: 2.426 conductive × Nu 1.006 + 3.439 radiative W/(m²·K).
Center and edge heat flow
Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A
ΣR = 0.352 m²·K/W, edge addition 0.195 W/(m²·K).
Solar gain
SHGC = τsolar + αsolar·Rout/Rtotal
Inward absorbed fraction 12.22 %, SHGC 0.706.
Condensation margin
Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp
Magnus dew point 8.021 °C, surface 9.668 °C, margin 1.646 K.