Summer solar-control facade

A warm outside boundary and solar-control outer pane represent a summer design day.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
m
m
Exterior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The center of glass is at least 2 K above the indoor dew point.

Pass
Glass U-factor
1.203W/(m²·K)
Glass SHGC
0.284
Glass surface
26°C
Dew margin
11.63K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 1.203 W/(m²·K). Glass SHGC 0.284. Glass surface 26 °C. Dew margin 11.63 K.Insulating glass section2 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side37 °C24 °CGlass profileDew 14.4 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
14.4 °C
Glass plus linear edge U-factor
1.3 W/(m²·K)
Linear spacer transmittance Ψ
0.04 W/(m·K)
Heat flux toward exterior
-15.64 W/m²
Cavity 1 gas conductance
1.228 W/(m²·K)
Cavity 1 radiative conductance
0.317 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 1.197 conductive × Nu 1.026 + 0.317 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 0.831 m²·K/W, edge addition 0.097 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 5.29 %, SHGC 0.284.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 14.4 °C, surface 26.031 °C, margin 11.631 K.