IGU U-factor, SHGC and condensation calculator

Model vertical double or triple glazing and compare the room-side glass temperature with indoor dew point.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
m
m
Exterior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The center of glass is at least 2 K above the indoor dew point.

Pass
Glass U-factor
1.36W/(m²·K)
Glass SHGC
0.496
Glass surface
15.2°C
Dew margin
5K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 1.36 W/(m²·K). Glass SHGC 0.496. Glass surface 15.2 °C. Dew margin 5 K.Insulating glass section2 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side-12 °C21 °CGlass profileDew 10.2 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
10.175 °C
Glass plus linear edge U-factor
1.457 W/(m²·K)
Linear spacer transmittance Ψ
0.04 W/(m·K)
Heat flux toward exterior
44.88 W/m²
Cavity 1 gas conductance
1.571 W/(m²·K)
Cavity 1 radiative conductance
0.236 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 1.177 conductive × Nu 1.335 + 0.236 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 0.735 m²·K/W, edge addition 0.097 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 5.85 %, SHGC 0.496.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 10.175 °C, surface 15.172 °C, margin 4.997 K.