GlassFacadeLab · Center-of-glass thermal model
Narrow krypton triple unit
Worked example · SI
Pass · The center of glass is at least 2 K above the indoor dew point.
Inputs
- Pane count
- Triple pane
- Outer pane
- 6 mm
- Inner pane
- 6 mm
- Middle pane
- 4 mm
- Unit width
- 0.92 m
- Unit height
- 1.42 m
- Gas fill
- Krypton
- Cavity width
- 7 mm
- Outer-facing emissivity ε₁
- 0.05
- Inner-facing emissivity ε₂
- 0.84
- Gas fill
- Krypton
- Cavity width
- 8 mm
- Outer-facing emissivity ε₁
- 0.84
- Inner-facing emissivity ε₂
- 0.06
- Indoor air temperature
- 21 °C
- Outdoor air temperature
- -20 °C
- Indoor relative humidity
- 53 %
- Spacer Ψ-edge
- Warm edge · 0.04 SI
- Assembly solar transmittance
- 0.48
- Assembly solar absorptance
- 0.28
- Absorbed heat location
- Outer pane
Results
- Glass U-factor
- 0.645 W/(m²·K)
- Glass SHGC
- 0.488
- Glass surface
- 17.6 °C
- Dew margin
- 6.52 K
- Indoor dew point
- 11.051 °C
- Glass plus linear edge U-factor
- 0.788 W/(m²·K)
- Linear spacer transmittance Ψ
- 0.04 W/(m·K)
- Heat flux toward exterior
- 26.43 W/m²
- Cavity 1 gas conductance
- 1.252 W/(m²·K)
- Cavity 1 radiative conductance
- 0.206 W/(m²·K)
- Cavity 2 gas conductance
- 1.171 W/(m²·K)
- Cavity 2 radiative conductance
- 0.301 W/(m²·K)
Formula trace in SI
Gas and radiation
hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)
Gap 1: 1.198 conductive × Nu 1.045 + 0.206 radiative W/(m²·K). Gap 2: 1.113 conductive × Nu 1.053 + 0.301 radiative W/(m²·K).
Center and edge heat flow
Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A
ΣR = 1.551 m²·K/W, edge addition 0.143 W/(m²·K).
Solar gain
SHGC = τsolar + αsolar·Rout/Rtotal
Inward absorbed fraction 2.77 %, SHGC 0.488.
Condensation margin
Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp
Magnus dew point 11.051 °C, surface 17.568 °C, margin 6.517 K.