Office tower corner lite

A heat-strengthened punched lite faces the local suction at a tower corner.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Linear center bow exceeds one glass thickness. Review large-deflection behavior.

Warn
Linear bow
11.54mm
Center stress
26.45MPa
Screening LR
5.64kPa
Load use
56.8%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 11.54 mm. Center stress 26.45 MPa. Screening LR 5.64 kPa. Load use 56.8 %.Four-edge-supported liteHeight 2.65 m · pressure 3.2 kPaa = 1.35 mPressure vs. center bowPressure (kPa)3.70014.07 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
1.963
Restrained-model center bow
7.755 mm
Restrained-model center stress
20.938 MPa
Selected center-bow limit
19 mm
Linear bow utilization
60.7 %
Glass type factor
2

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 11.45 mm, D = 9201.928 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.009992, aₛ = 1.35 m, w₀ = 11.541 mm.

  3. Restrained response

    q = kb w + km w³

    q = 3.2 kPa, w = 7.755 mm, σ = 20.938 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 2, LR 5.638 kPa, load use 56.75 %, bow use 60.74 %.