Annealed retail storefront

A small recessed storefront uses annealed glass on four continuous supports.

ASTM E1300 · Roark plate screening

Inputs

Glass lite
m
m
mm
mm

Use the minimum thickness certified for the lite.

MPa

Editable screening assumption.

Load and limit
kPa

Factor on reference resistance. Use 1 for the default short-load screen.

Screening result

Wind demand and linear bow are within the selected limits.

Pass
Linear bow
2.23mm
Center stress
7.35MPa
Screening LR
2.85kPa
Load use
31.5%
Glass-lite elevation and load–deflection curveGlass plate wind load. Linear bow 2.23 mm. Center stress 7.35 MPa. Screening LR 2.85 kPa. Load use 31.5 %.Four-edge-supported liteHeight 1.65 m · pressure 0.9 kPaa = 0.92 mPressure vs. center bowPressure (kPa)1002.71 mmLinearRestrainedGoverning demand0%100% limit200%+

Calculation details

Entered aspect b/a
1.793
Restrained-model center bow
2.067 mm
Restrained-model center stress
7.317 MPa
Selected center-bow limit
15.333 mm
Linear bow utilization
14.5 %
Glass type factor
1

Formula trace in SI

  1. Flexural rigidity

    D = E t³ / [12(1 − ν²)]

    t = 7.6 mm, D = 2690.935 N·m.

  2. Linear response

    w₀ = Cw q aₛ⁴ / D; σ = 6 max(Mx, My) / t²

    Cw = 0.009286, aₛ = 0.92 m, w₀ = 2.225 mm.

  3. Restrained response

    q = kb w + km w³

    q = 0.9 kPa, w = 2.067 mm, σ = 7.317 MPa.

  4. Resistance and demand

    LR = σref × GTF × duration / Cσ, with σlinear = Cσ q

    GTF 1, LR 2.853 kPa, load use 31.54 %, bow use 14.51 %.