Clear air-filled storefront IGU

A renovation reuses double clear panes with an air cavity and a metal spacer.

Center-of-glass thermal model

Inputs

Glazing build-up
mm
mm
m
m
Exterior cavity
mm
Climate and solar data
°C
°C
%

Screening result

The glass is at the dew point or within 2 K of it.

Warn
Glass U-factor
2.841W/(m²·K)
Glass SHGC
0.706
Glass surface
9.7°C
Dew margin
1.65K
Insulating glass section and temperature profileIGU heat and condensation. Glass U-factor 2.841 W/(m²·K). Glass SHGC 0.706. Glass surface 9.7 °C. Dew margin 1.65 K.Insulating glass section2 panes · sealed vertical cavitiesExteriorInteriorTemperature profileOutdoor to room side-8 °C20 °CGlass profileDew 8 °CCenter-glass dew margin−5 KDew point+5 K

Calculation details

Indoor dew point
8.021 °C
Glass plus linear edge U-factor
3.036 W/(m²·K)
Linear spacer transmittance Ψ
0.08 W/(m·K)
Heat flux toward exterior
79.56 W/m²
Cavity 1 gas conductance
2.44 W/(m²·K)
Cavity 1 radiative conductance
3.439 W/(m²·K)

Formula trace in SI

  1. Gas and radiation

    hgap = Nu·k/d + σεeff(T₁ + T₂)(T₁² + T₂²)

    Gap 1: 2.426 conductive × Nu 1.006 + 3.439 radiative W/(m²·K).

  2. Center and edge heat flow

    Uc = 1/ΣR; Uglass+edge = Uc + ΨP/A

    ΣR = 0.352 m²·K/W, edge addition 0.195 W/(m²·K).

  3. Solar gain

    SHGC = τsolar + αsolar·Rout/Rtotal

    Inward absorbed fraction 12.22 %, SHGC 0.706.

  4. Condensation margin

    Tsi = Ti − q/hin; ΔTdew = Tsi − Tdp

    Magnus dew point 8.021 °C, surface 9.668 °C, margin 1.646 K.