HeatExchangerLab

High-chevron pack for a wall shear check

The design uses narrow 60° channels to raise velocity and shear in a fouling-sensitive liquid service.

Chevron plate pack

Nactive ≥ Q / (U × ΔT × Aplate) · τw = fᴅρv²/8

Edit inputs ↓
Plate count
53
Channel speed
1.7258m/s
Wall shear
660.08Pa
Plate ΔP
637.92kPa
Chevron plate packCORRUGATED PLATESCHANNEL SECTION60° chevronShear 660.08 Pa2.8 mm gap050 Pa screen100 Pa+
Chevron angle changes the ribs. The channel gap is enlarged. The shear bar uses a 50 Pa screen and caps at 100 Pa. The channel label shows the calculated shear.
  • Within the displayed screening checks.

Inputs

kW
W/(m²·K)
K
m
m
mm
L/min
kg/m³
mPa·s

Calculated results

Installed plates
53
Channel velocity
1.7258 m/s
Average wall shear
660.08 Pa
Core pressure drop
637.92 kPa
Active thermal plates
51
Channels per side per pass
26
Hydraulic diameter
4.5528 mm
Channel Reynolds number
7,107.4
Required transfer area
26.638 m²
Area per active plate
0.52767 m²
Installed transfer area
26.911 m²
Darcy friction factor
1.7818

Worked solution

Preset calculation · Metric SI

  1. Divide target duty by service U times corrected mean ΔT. The required transfer area is 26.638 m².
  2. Each active plate contributes 0.52767 m². The balanced pack uses 53 plates including the two end plates.
  3. Use 26 channels per side per pass to find velocity. The chevron model gives 660.08 Pa wall shear and 637.92 kPa core loss.

Compare the shear marker with 50 Pa and check the associated core pressure drop before increasing pass count.

Calculation basis

Use active plate width and length, excluding the port area. Corrugation enlargement multiplies projected plate area. The pack includes two non-transfer end plates and rounds up to equal channels per side and pass.

The hydraulics are for the entered stream. Hydraulic diameter is 2b/φ. A Martin chevron friction factor estimates core pressure drop and average wall shear. Port and multi-pass turning losses are omitted.

Wall shear over 50 Pa is an illustrative antifouling screen. Use supplier predictions and fluid-specific deposition data for final selection.

Methodology and references