HeatExchangerLab

One-pass wort cooling plate pack

A gasketed plate pack cools a batch of wort using a specified service coefficient and corrected temperature drive.

Chevron plate pack

Nactive ≥ Q / (U × ΔT × Aplate) · τw = fᴅρv²/8

Edit inputs ↓
Plate count
65
Channel speed
0.72805m/s
Wall shear
60.422Pa
Plate ΔP
48.244kPa
Chevron plate packCORRUGATED PLATESCHANNEL SECTION45° chevronShear 60.422 Pa3.1 mm gap050 Pa screen100 Pa+
Chevron angle changes the ribs. The channel gap is enlarged. The shear bar uses a 50 Pa screen and caps at 100 Pa. The channel label shows the calculated shear.
  • Within the displayed screening checks.

Inputs

kW
W/(m²·K)
K
m
m
mm
L/min
kg/m³
mPa·s

Calculated results

Installed plates
65
Channel velocity
0.72805 m/s
Average wall shear
60.422 Pa
Core pressure drop
48.244 kPa
Active thermal plates
63
Channels per side per pass
32
Hydraulic diameter
5.2101 mm
Channel Reynolds number
2,304.6
Required transfer area
27.755 m²
Area per active plate
0.44554 m²
Installed transfer area
28.069 m²
Darcy friction factor
0.87267

Worked solution

Preset calculation · Metric SI

  1. Divide target duty by service U times corrected mean ΔT. The required transfer area is 27.755 m².
  2. Each active plate contributes 0.44554 m². The balanced pack uses 65 plates including the two end plates.
  3. Use 32 channels per side per pass to find velocity. The chevron model gives 60.422 Pa wall shear and 48.244 kPa core loss.

Compare active and total plates, then read the channel shear for the chosen fluid.

Calculation basis

Use active plate width and length, excluding the port area. Corrugation enlargement multiplies projected plate area. The pack includes two non-transfer end plates and rounds up to equal channels per side and pass.

The hydraulics are for the entered stream. Hydraulic diameter is 2b/φ. A Martin chevron friction factor estimates core pressure drop and average wall shear. Port and multi-pass turning losses are omitted.

Wall shear over 50 Pa is an illustrative antifouling screen. Use supplier predictions and fluid-specific deposition data for final selection.

Methodology and references