Wide-gap plate pack for viscous product
A viscous food-process liquid uses wider plate channels and shallow corrugations.
Chevron plate pack
Nactive ≥ Q / (U × ΔT × Aplate) · τw = fᴅρv²/8
- Plate count
- 51
- Channel speed
- 0.22055m/s
- Wall shear
- 8.1864Pa
- Plate ΔP
- 3.427kPa
- Average wall shear does not exceed the 50 Pa antifouling screen.
- Reynolds number is outside the 200–10,000 range used for this plate screening correlation.
Inputs
Calculated results
- Installed plates
- 51
- Channel velocity
- 0.22055 m/s
- Average wall shear
- 8.1864 Pa
- Core pressure drop
- 3.427 kPa
- Active thermal plates
- 49
- Channels per side per pass
- 25
- Hydraulic diameter
- 12.613 mm
- Channel Reynolds number
- 111.27
- Required transfer area
- 40 m²
- Area per active plate
- 0.83516 m²
- Installed transfer area
- 40.923 m²
- Darcy friction factor
- 1.2021
Worked solution
Preset calculation · Metric SI
- Divide target duty by service U times corrected mean ΔT. The required transfer area is 40 m².
- Each active plate contributes 0.83516 m². The balanced pack uses 51 plates including the two end plates.
- Use 25 channels per side per pass to find velocity. The chevron model gives 8.1864 Pa wall shear and 3.427 kPa core loss.
Inspect the resulting Reynolds number. The correlation warning helps flag low-flow extrapolation.
Calculation basis
Use active plate width and length, excluding the port area. Corrugation enlargement multiplies projected plate area. The pack includes two non-transfer end plates and rounds up to equal channels per side and pass.
The hydraulics are for the entered stream. Hydraulic diameter is 2b/φ. A Martin chevron friction factor estimates core pressure drop and average wall shear. Port and multi-pass turning losses are omitted.
Wall shear over 50 Pa is an illustrative antifouling screen. Use supplier predictions and fluid-specific deposition data for final selection.
Methodology and references