One-pass wort cooling plate pack
A gasketed plate pack cools a batch of wort using a specified service coefficient and corrected temperature drive.
Chevron plate pack
Nactive ≥ Q / (U × ΔT × Aplate) · τw = fᴅρv²/8
- Plate count
- 65
- Channel speed
- 0.72805m/s
- Wall shear
- 60.422Pa
- Plate ΔP
- 48.244kPa
- Within the displayed screening checks.
Inputs
Calculated results
- Installed plates
- 65
- Channel velocity
- 0.72805 m/s
- Average wall shear
- 60.422 Pa
- Core pressure drop
- 48.244 kPa
- Active thermal plates
- 63
- Channels per side per pass
- 32
- Hydraulic diameter
- 5.2101 mm
- Channel Reynolds number
- 2,304.6
- Required transfer area
- 27.755 m²
- Area per active plate
- 0.44554 m²
- Installed transfer area
- 28.069 m²
- Darcy friction factor
- 0.87267
Worked solution
Preset calculation · Metric SI
- Divide target duty by service U times corrected mean ΔT. The required transfer area is 27.755 m².
- Each active plate contributes 0.44554 m². The balanced pack uses 65 plates including the two end plates.
- Use 32 channels per side per pass to find velocity. The chevron model gives 60.422 Pa wall shear and 48.244 kPa core loss.
Compare active and total plates, then read the channel shear for the chosen fluid.
Calculation basis
Use active plate width and length, excluding the port area. Corrugation enlargement multiplies projected plate area. The pack includes two non-transfer end plates and rounds up to equal channels per side and pass.
The hydraulics are for the entered stream. Hydraulic diameter is 2b/φ. A Martin chevron friction factor estimates core pressure drop and average wall shear. Port and multi-pass turning losses are omitted.
Wall shear over 50 Pa is an illustrative antifouling screen. Use supplier predictions and fluid-specific deposition data for final selection.
Methodology and references