Chevron plate pack

Nactive ≥ Q / (U × ΔT × Aplate) · τw = fᴅρv²/8

Edit inputs ↓
Plate count
51
Channel speed
0.22055m/s
Wall shear
8.1864Pa
Plate ΔP
3.427kPa
Chevron plate packCORRUGATED PLATESCHANNEL SECTION30° chevronShear 8.1864 Pa7 mm gap050 Pa screen100 Pa+
Chevron angle changes the ribs. The channel gap is enlarged. The shear bar uses a 50 Pa screen and caps at 100 Pa. The channel label shows the calculated shear.
  • Average wall shear does not exceed the 50 Pa antifouling screen.
  • Reynolds number is outside the 200–10,000 range used for this plate screening correlation.

Inputs

kW
W/(m²·K)
K
m
m
mm
L/min
kg/m³
mPa·s

Calculated results

Installed plates
51
Channel velocity
0.22055 m/s
Average wall shear
8.1864 Pa
Core pressure drop
3.427 kPa
Active thermal plates
49
Channels per side per pass
25
Hydraulic diameter
12.613 mm
Channel Reynolds number
111.27
Required transfer area
40 m²
Area per active plate
0.83516 m²
Installed transfer area
40.923 m²
Darcy friction factor
1.2021

Worked solution

Preset calculation · Metric SI

  1. Divide target duty by service U times corrected mean ΔT. The required transfer area is 40 m².
  2. Each active plate contributes 0.83516 m². The balanced pack uses 51 plates including the two end plates.
  3. Use 25 channels per side per pass to find velocity. The chevron model gives 8.1864 Pa wall shear and 3.427 kPa core loss.

Inspect the resulting Reynolds number. The correlation warning helps flag low-flow extrapolation.

Calculation basis

Use active plate width and length, excluding the port area. Corrugation enlargement multiplies projected plate area. The pack includes two non-transfer end plates and rounds up to equal channels per side and pass.

The hydraulics are for the entered stream. Hydraulic diameter is 2b/φ. A Martin chevron friction factor estimates core pressure drop and average wall shear. Port and multi-pass turning losses are omitted.

Wall shear over 50 Pa is an illustrative antifouling screen. Use supplier predictions and fluid-specific deposition data for final selection.