One-minute ventilation for a 12×20 ft greenhouse

For an initial summer ventilation check, approximate the greenhouse as 12×20 ft with an average air height of 8 ft. Use no duct or filter allowance for the direct exhaust baseline.

Inputs

Room size and ventilation
ft
ft
ft
min
Airflow resistance allowances
%
ft
% / 10 ft
%

Results

Estimated free-air rating

1,920 CFM

60 air changes/hour · 100% modeled airflow retained

Room volume
1,920 ft³
Room volume
54.37 m³
Target delivered airflow
1,920 CFM
Target delivered airflow
3,262.1 m³/h
Estimated free-air rating
1,920 CFM
Estimated free-air rating
3,262.1 m³/h

Delivered flow and fan rating

Compare required delivery with the estimated no-restriction rating.

Exhaust fan airflow comparisonDelivered airflow: 1,920 CFM. Estimated free-air rating: 1,920 CFMDelivered airflow1,920 CFMEstimated free-air rating1,920 CFM

Worked calculation

  1. Measure interior air volume

    20 ft × 12 ft × 8 ft = 1,920 ft³

  2. Find the delivered airflow needed

    1,920 ft³ ÷ 1 min = 1,920 CFM

  3. Multiply retained fractions

    1 filter × 1 duct × 1 elbows = 100% retained

  4. Find the estimated free-air rating

    1,920 CFM ÷ 1 = 1,920 CFM (3,262.1 m³/h)

What the example shows

Volume divided by one minute gives 1,920 CFM delivered. Include the installed louver, screen and intake resistance when evaluating equipment.

How the model works

Filter, duct and elbow inputs are planning allowances. Duct loss compounds over each 10 ft equivalent, and elbow loss compounds for each fitting. Pressure drop depends on airflow, duct diameter, filter loading and fitting geometry.

Select a fan using its CFM at the operating static pressure for your system. Use the estimated free-air rating as a screening number. Check intake area, ventilation demand from heat and moisture, and the installed fan curve.

References

Common questions

Which height belongs in a sloped 12×20 greenhouse volume estimate?

Use the volume-equivalent average height. A gable with uniform cross-section averages the eave and ridge heights.

Can I split 1,920 CFM between multiple fans?

Yes, assess the fans’ combined delivered airflow at their installed pressure. Check intake distribution and whether control stages cover the expected load.