Two-minute air exchange for a 2×4 grow tent
The interior measures 2×4×6 ft. It uses four feet of duct and one 90° elbow, and no filter is installed.
Inputs
Results
Estimated free-air rating
30 air changes/hour · 93.1% modeled airflow retained
- Room volume
- 48 ft³
- Room volume
- 1.36 m³
- Target delivered airflow
- 24 CFM
- Target delivered airflow
- 40.8 m³/h
- Estimated free-air rating
- 25.8 CFM
- Estimated free-air rating
- 43.8 m³/h
Delivered flow and fan rating
Compare required delivery with the estimated no-restriction rating.
Inputs used
- Interior length
- 2 ft
- Interior width
- 4 ft
- Interior height
- 6 ft
- Time per air exchange
- 2 min
- Carbon filter loss
- 0 %
- Straight duct run
- 4 ft
- Duct loss per reference length
- 5 % / 10 ft
- 90° elbows
- 1
- Loss per elbow
- 5 %
Worked calculation
- Measure interior air volume
2 ft × 4 ft × 6 ft = 48 ft³
- Find the delivered airflow needed
48 ft³ ÷ 2 min = 24 CFM
- Multiply retained fractions
1 filter × 0.97969 duct × 0.95 elbows = 93.07% retained
- Find the estimated free-air rating
24 CFM ÷ 0.93071 = 25.79 CFM (43.8 m³/h)
What the example shows
A two-minute exchange needs about 24 CFM delivered. The modeled short duct and elbow raise the free-air estimate to approximately 25.8 CFM.
How the model works
Filter, duct and elbow inputs are planning allowances. Duct loss compounds over each 10 ft equivalent, and elbow loss compounds for each fitting. Pressure drop depends on airflow, duct diameter, filter loading and fitting geometry.
Select a fan using its CFM at the operating static pressure for your system. Use the estimated free-air rating as a screening number. Check intake area, ventilation demand from heat and moisture, and the installed fan curve.
References
Common questions
Can I use the same 24 CFM if the 2×4 tent adds a carbon filter?
Keep 24 CFM as the delivered target and increase modeled resistance to reflect the new filter. Verify its pressure drop at the intended flow.
How do I include a small duct length like four feet?
Enter the measured straight run. The model applies a fraction of the per-10-foot duct allowance for shorter lengths.