Three-minute air exchange in a 3×3 grow tent
A 54 ft³ tent uses a modest air-exchange setting of once per three minutes. Estimate a 15% filter loss and one 90° elbow with an 8% allowance.
Inputs
Results
Estimated free-air rating
20 air changes/hour · 75.8% modeled airflow retained
- Room volume
- 54 ft³
- Room volume
- 1.53 m³
- Target delivered airflow
- 18 CFM
- Target delivered airflow
- 30.6 m³/h
- Estimated free-air rating
- 23.7 CFM
- Estimated free-air rating
- 40.3 m³/h
Delivered flow and fan rating
Compare required delivery with the estimated no-restriction rating.
Inputs used
- Interior length
- 3 ft
- Interior width
- 3 ft
- Interior height
- 6 ft
- Time per air exchange
- 3 min
- Carbon filter loss
- 15 %
- Straight duct run
- 6 ft
- Duct loss per reference length
- 5 % / 10 ft
- 90° elbows
- 1
- Loss per elbow
- 8 %
Worked calculation
- Measure interior air volume
3 ft × 3 ft × 6 ft = 54 ft³
- Find the delivered airflow needed
54 ft³ ÷ 3 min = 18 CFM
- Multiply retained fractions
0.85 filter × 0.96969 duct × 0.92 elbows = 75.83% retained
- Find the estimated free-air rating
18 CFM ÷ 0.7583 = 23.74 CFM (40.3 m³/h)
What the example shows
The delivered target is 18 CFM, and the rough free-air rating is 23.7 CFM. Watch canopy temperature and humidity to see whether the target is sufficient.
How the model works
Filter, duct and elbow inputs are planning allowances. Duct loss compounds over each 10 ft equivalent, and elbow loss compounds for each fitting. Pressure drop depends on airflow, duct diameter, filter loading and fitting geometry.
Select a fan using its CFM at the operating static pressure for your system. Use the estimated free-air rating as a screening number. Check intake area, ventilation demand from heat and moisture, and the installed fan curve.
References
Common questions
Is a three-minute exchange always adequate for a 3×3 tent?
It depends on the heat load, humidity production and intake conditions. Compare measured temperature and RH under the normal lighting and irrigation schedule.
What happens to CFM if I move this tent from three minutes to one?
At the same volume and restrictions, the required delivered airflow and the screening free-air estimate both triple.