Corridor with a custom allowance
Enter a project-specific LPD limit for an adopted energy code. Higher retrofit fixture watts in this case make energy savings negative.
Inputs
View results ↑- Actual LPD
- 0.405W/ft²
- LPD margin
- -22.7%
- Energy saved
- -122.4kWh/yr
- Payback
- —
Installed power and allowance
Edit inputs ↓Connected LPD screen
Review neededOutsideThresholdWithin
- Connected power density0.4 / ≤ 0.33 W/ft² outside screen
Comparison uses the custom project allowance.
Additional readings
| Selected LPD allowance | 0.33W/ft² |
|---|---|
| Connected load | 340W |
| Connected power allowance | 277.2W |
| Allowance minus connected load | -62.8W |
| Equivalent controlled load | 340W |
| Legacy lighting energy | 1,101.6kWh/yr |
| Post-retrofit lighting energy | 1,224kWh/yr |
| Annual utility savings | -20.81USD/yr |
Worked calculation
US customary results for the original preset.
- Divide 340 W of connected load by 840 ft² to get 0.405 W/ft². The selected limit is 0.33 W/ft².
- After applying the control credit to annual use, compare 1101.6 kWh/yr before retrofit with 1224 kWh/yr after retrofit.
- At 0.17 USD/kWh, the annual cost difference is -20.81 USD/yr. Payback is undefined because annual savings are zero or negative.
Calculation method
Presets use the I-P ASHRAE 90.1-2019 Table 9.6.1 base allowances. Select Custom for an adopted IECC or other project-specific allowance.
- Connected lighting power density
- LPD = fixture count × input watts/floor area
- Annual energy savings
- ΔkWh = (legacy watts − installed watts × (1 − control credit)) × hours/1000
- Simple payback
- Years = retrofit cost/(ΔkWh × utility rate), when savings are positive
Classifications, exemptions, additional allowances and mandatory controls require project review. Enter control savings as an annual energy assumption.
Sources and assumptions ↗LightingLuxLab · US customary
Corridor with a custom allowance
Inputs
| Space type | Custom allowance · project or IECC |
|---|---|
| Custom LPD limit | 0.33W/ft² |
| Lighted floor area | 840ft² |
| Fixture count | 17 |
| Installed watts per fixture | 20W |
| Control energy credit | 0% |
| Operating hours | 3,600h/yr |
| Legacy watts per fixture | 18W |
| Electricity rate | 0.17USD/kWh |
| Retrofit capital cost | 950USD |
Results
| Actual LPD | 0.405W/ft² |
|---|---|
| LPD margin | -22.7% |
| Energy saved | -122.4kWh/yr |
| Payback | — |
| Selected LPD allowance | 0.33W/ft² |
| Connected load | 340W |
| Connected power allowance | 277.2W |
| Allowance minus connected load | -62.8W |
| Equivalent controlled load | 340W |
| Legacy lighting energy | 1,101.6kWh/yr |
| Post-retrofit lighting energy | 1,224kWh/yr |
| Annual utility savings | -20.81USD/yr |
Connected LPD screen
- Connected power density · 0.4 / ≤ 0.33 W/ft² · Outside screen
Comparison uses the custom project allowance.
Classifications, exemptions, additional allowances and mandatory controls require project review. Enter control savings as an annual energy assumption.