General classroom LED retrofit
Estimate savings in a standard classroom with scheduling controls and a relatively short operating year.
Inputs
View results ↑- Actual LPD
- 0.48W/ft²
- LPD margin
- 32.4%
- Energy saved
- 659.3kWh/yr
- Payback
- 14.1yr
Installed power and allowance
Edit inputs ↓Connected LPD screen
Within screen- Connected power density0.48 / ≤ 0.71 W/ft² within screen
Comparison uses the 90.1-2019 Space-by-Space base allowance without control credits.
Additional readings
| Selected LPD allowance | 0.71W/ft² |
|---|---|
| Connected load | 432W |
| Connected power allowance | 639W |
| Allowance minus connected load | 207W |
| Equivalent controlled load | 380.16W |
| Legacy lighting energy | 1,305.6kWh/yr |
| Post-retrofit lighting energy | 646.27kWh/yr |
| Annual utility savings | 92.31USD/yr |
Worked calculation
US customary results for the original preset.
- Divide 432 W of connected load by 900 ft² to get 0.48 W/ft². The selected limit is 0.71 W/ft².
- After applying the control credit to annual use, compare 1305.6 kWh/yr before retrofit with 646.3 kWh/yr after retrofit.
- At 0.14 USD/kWh, the annual cost difference is 92.31 USD/yr. Simple payback is 14.08 yr.
Calculation method
Presets use the I-P ASHRAE 90.1-2019 Table 9.6.1 base allowances. Select Custom for an adopted IECC or other project-specific allowance.
- Connected lighting power density
- LPD = fixture count × input watts/floor area
- Annual energy savings
- ΔkWh = (legacy watts − installed watts × (1 − control credit)) × hours/1000
- Simple payback
- Years = retrofit cost/(ΔkWh × utility rate), when savings are positive
Classifications, exemptions, additional allowances and mandatory controls require project review. Enter control savings as an annual energy assumption.
Sources and assumptions ↗General classroom LED retrofit
Inputs
| Space type | Classroom · general |
|---|---|
| Lighted floor area | 900ft² |
| Fixture count | 12 |
| Installed watts per fixture | 36W |
| Control energy credit | 12% |
| Operating hours | 1,700h/yr |
| Legacy watts per fixture | 64W |
| Electricity rate | 0.14USD/kWh |
| Retrofit capital cost | 1,300USD |
Results
| Actual LPD | 0.48W/ft² |
|---|---|
| LPD margin | 32.4% |
| Energy saved | 659.3kWh/yr |
| Payback | 14.1yr |
| Selected LPD allowance | 0.71W/ft² |
| Connected load | 432W |
| Connected power allowance | 639W |
| Allowance minus connected load | 207W |
| Equivalent controlled load | 380.16W |
| Legacy lighting energy | 1,305.6kWh/yr |
| Post-retrofit lighting energy | 646.27kWh/yr |
| Annual utility savings | 92.31USD/yr |
Connected LPD screen
- Connected power density · 0.48 / ≤ 0.71 W/ft² · Within screen
Comparison uses the 90.1-2019 Space-by-Space base allowance without control credits.
Classifications, exemptions, additional allowances and mandatory controls require project review. Enter control savings as an annual energy assumption.