Custom screw and measured stiffness

A custom screw has a test-supplied tensile area and strength, along with measured stiffnesses.

Input units
Load fraction 0.27066
Bolt tension 29,966 N
Clamp force 13,466 N
Separation 34,963 N

Anatomy

Bolt extension and clamp release

Edit inputs
Bolt extension and clamp releaseSchematic view with the current loads and dimensions. JOINT SECTIONJOINT FORCEExternal pull PAxial displacementPreload Fᵢ25,500 NBolt Fᵦ29,970 NClamp Fₘ13,470 N

Screening margins

Within screen
  • Separation16,500 N / 34,960 N
    Within screen
  • Bolt proof load29,970 N / 45,600 N
    Within screen
  • Goodman fatigue68.56% of limit
    Within screen

Calculated values

Bolt load fraction C0.27066
Peak bolt tension Fᵦ29,966 N
Remaining clamp Fₘ13,466 N
External separation load Pₛₑₚ34,963 N
Tensile stress area Aₜ60 mm²
Bolt proof strength Sₚ760 MPa
Axial bolt stiffness kᵦ475,000 N/mm
Axial member stiffness kₘ1.28e6 N/mm
Linear clamp reserve13,466 N
Bolt proof load45,600 N
Separation factor n₀2.119 ×
Proof factor nₚ1.5217 ×
Cycle mean tensile stress466.73 MPa
Alternating tensile stress32.704 MPa
Nominal Goodman factor1.4587 ×

Starting result

Using the custom material and stiffness inputs allows the same load and fatigue screen without a thread preset.

Bolt proof load
45,600 N
Alternating tensile stress
32.704 MPa
Nominal Goodman factor
1.4587 ×

Model and assumptions

C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation

Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.

References and calculation method

Worked examples

Open the standard calculator