Metric joint under static tension
An M10 class 8.8 screw clamps two members under a steady centered separating load.
Input units
Load fraction
0.20023
Bolt tension
25,703
N
Clamp force
12,203
N
Separation
28,758
N
Anatomy
Bolt extension and clamp release
Screening margins
Within screen-
Separation13,500 N / 28,760 N
Within screen -
Bolt proof load25,700 N / 33,640 N
Within screen
Calculated values
| Bolt load fraction C | 0.20023 |
|---|---|
| Peak bolt tension Fᵦ | 25,703 N |
| Remaining clamp Fₘ | 12,203 N |
| External separation load Pₛₑₚ | 28,758 N |
| Tensile stress area Aₜ | 58 mm² |
| Bolt proof strength Sₚ | 580 MPa |
| Axial bolt stiffness kᵦ | 583,840 N/mm |
| Axial member stiffness kₘ | 2.3321e6 N/mm |
| Linear clamp reserve | 12,203 N |
| Bolt proof load | 33,640 N |
| Separation factor n₀ | 2.1302 × |
| Proof factor nₚ | 1.3088 × |
| Cycle mean tensile stress | — |
| Alternating tensile stress | — |
| Nominal Goodman factor | — |
Starting result
The external load divides between bolt loading and clamp release until the interface opens.
- Tensile stress area Aₜ
- 58 mm²
- Peak bolt tension Fᵦ
- 25,703 N
- Remaining clamp Fₘ
- 12,203 N
Model and assumptions
C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation
Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.
References and calculation method