Repeated joint tension cycle
An M16 screw experiences a load cycle between 4 kN and 42 kN.
Input units
Load fraction
0.1929
Bolt tension
80,602
N
Clamp force
38,602
N
Separation
89,827
N
Anatomy
Bolt extension and clamp release
Screening margins
Within screen-
Separation42,000 N / 89,830 N
Within screen -
Bolt proof load80,600 N / 130,300 N
Within screen -
Goodman fatigue59.41% of limit
Within screen
Calculated values
| Bolt load fraction C | 0.1929 |
|---|---|
| Peak bolt tension Fᵦ | 80,602 N |
| Remaining clamp Fₘ | 38,602 N |
| External separation load Pₛₑₚ | 89,827 N |
| Tensile stress area Aₜ | 157 mm² |
| Bolt proof strength Sₚ | 830 MPa |
| Axial bolt stiffness kᵦ | 834,230 N/mm |
| Axial member stiffness kₘ | 3.4905e6 N/mm |
| Linear clamp reserve | 38,602 N |
| Bolt proof load | 130,310 N |
| Separation factor n₀ | 2.1387 × |
| Proof factor nₚ | 1.6167 × |
| Cycle mean tensile stress | 490.04 MPa |
| Alternating tensile stress | 23.344 MPa |
| Nominal Goodman factor | 1.6833 × |
Starting result
The bolt stress amplitude follows the alternating part of bolt force, while mean stress includes preload.
- Cycle mean tensile stress
- 490.04 MPa
- Alternating tensile stress
- 23.344 MPa
- Nominal Goodman factor
- 1.6833 ×
Model and assumptions
C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation
Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.
References and calculation method