Metric joint under static tension

An M10 class 8.8 screw clamps two members under a steady centered separating load.

Input units
Load fraction 0.20023
Bolt tension 25,703 N
Clamp force 12,203 N
Separation 28,758 N

Anatomy

Bolt extension and clamp release

Edit inputs
Bolt extension and clamp releaseSchematic view with the current loads and dimensions. JOINT SECTIONJOINT FORCEExternal pull PAxial displacementPreload Fᵢ23,000 NBolt Fᵦ25,700 NClamp Fₘ12,200 N

Screening margins

Within screen
  • Separation13,500 N / 28,760 N
    Within screen
  • Bolt proof load25,700 N / 33,640 N
    Within screen

Calculated values

Bolt load fraction C0.20023
Peak bolt tension Fᵦ25,703 N
Remaining clamp Fₘ12,203 N
External separation load Pₛₑₚ28,758 N
Tensile stress area Aₜ58 mm²
Bolt proof strength Sₚ580 MPa
Axial bolt stiffness kᵦ583,840 N/mm
Axial member stiffness kₘ2.3321e6 N/mm
Linear clamp reserve12,203 N
Bolt proof load33,640 N
Separation factor n₀2.1302 ×
Proof factor nₚ1.3088 ×
Cycle mean tensile stress—
Alternating tensile stress—
Nominal Goodman factor—

Starting result

The external load divides between bolt loading and clamp release until the interface opens.

Tensile stress area Aₜ
58 mm²
Peak bolt tension Fᵦ
25,703 N
Remaining clamp Fₘ
12,203 N

Model and assumptions

C = kᵦ/(kᵦ+kₘ) · Fᵦ = Fᵢ+CP · Fₘ = Fᵢ−(1−C)P before separation

Centered axial tension with unit load introduction. The estimate uses bolt thread and shank compliance and two symmetric 30° member frusta. After separation the bolt carries the full load and retained clamp is zero.

References and calculation method

Worked examples

Open the standard calculator