- RAIDZ2 devotes two of eight drive equivalents to parity. 6 × 16 = 96 TB, or about 87.31 TiB before filesystem overhead.
- RAID 10 keeps four primary copies in four pairs. 4 × 16 = 64 TB, or about 58.21 TiB, before overhead.
- At full occupancy the model reads 112 TB for RAIDZ2 versus 16 TB for a mirror replacement. At 10¹⁵ bits per URE the modeled chances of at least one read error are about 59.18% and 12.01%.
Results
- Usable capacity
- 87.31 TiB
- 96 TB
- One-drive rebuild
- 1 d 5 h 37 min 47 s
- Chance of ≥1 URE
- 59.1801%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAIDZ2
- Raw capacity
- 128 TB
- Parity / mirror overhead
- 32 TB
- Capacity efficiency
- 75%
- Guaranteed failures tolerated
- 2
- Best-case failures tolerated
- 2
- Read peers
- 7
| Quantity | Estimate |
|---|---|
| Replacement writes | 16 TB |
| Peer reads | 112 TB |
| URE rating (bits per error) | 1e+15 |
Questions
Which eight-drive layout tolerates any two drive failures?
RAIDZ2 can tolerate any two drive failures in its vdev. RAID 10 can tolerate two when they hit different mirror pairs.
Does this 87.31 TiB RAIDZ2 figure match a new zpool exactly?
It is a parity-only estimate. ZFS metadata, record-size padding, reserved space and device geometry affect actual reported space.