Compare 8 × 16 TB RAIDZ2 and RAID 10 capacity

Compare usable TiB, fault tolerance and estimated URE exposure for eight 16 TB drives. Switch the layout to compare RAIDZ2 and RAID 10.

Try these inputs

Worked calculation

  1. RAIDZ2 devotes two of eight drive equivalents to parity. 6 × 16 = 96 TB, or about 87.31 TiB before filesystem overhead.
  2. RAID 10 keeps four primary copies in four pairs. 4 × 16 = 64 TB, or about 58.21 TiB, before overhead.
  3. At full occupancy the model reads 112 TB for RAIDZ2 versus 16 TB for a mirror replacement. At 10¹⁵ bits per URE the modeled chances of at least one read error are about 59.18% and 12.01%.

Inputs

Equal-size drives
Use a measured replacement-drive rate when available.

Calculated in your browser

Results

Usable capacity
87.31 TiB
96 TB
One-drive rebuild
1 d 5 h 37 min 47 s
Chance of ≥1 URE
59.1801%

Rebuild progress and URE probability

Rebuild progress and URE probabilityThe curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.URE probability · 60%0%Elapsed1 d 5 h 37 min 47 s59.1801%
  • Chance of at least one read error
The curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.
Layout
RAIDZ2
Raw capacity
128 TB
Parity / mirror overhead
32 TB
Capacity efficiency
75%
Guaranteed failures tolerated
2
Best-case failures tolerated
2
Read peers
7
Single-drive rebuild assumptions
QuantityEstimate
Replacement writes16 TB
Peer reads112 TB
URE rating (bits per error)1e+15

Questions

Which eight-drive layout tolerates any two drive failures?

RAIDZ2 can tolerate any two drive failures in its vdev. RAID 10 can tolerate two when they hit different mirror pairs.

Does this 87.31 TiB RAIDZ2 figure match a new zpool exactly?

It is a parity-only estimate. ZFS metadata, record-size padding, reserved space and device geometry affect actual reported space.

References