Calculate RAID 60 for 16 × 18 TB in four groups

Compare raw and usable space for four four-drive RAID 6 groups, then estimate the peer read volume for a single rebuild.

Try these inputs

Worked calculation

  1. Four equal groups of four drives each put two disk equivalents per group toward parity.
  2. Data capacity is (16 − 4 × 2) × 18 = 144 TB. Total raw capacity is 288 TB.
  3. A failed drive involves its own three surviving peers, or 54 TB of full-member reads. Two failures are guaranteed across placements, with up to eight if every group loses two.

Inputs

Equal-size drives
Use a measured replacement-drive rate when available.

Calculated in your browser

Results

Usable capacity
130.97 TiB
144 TB
One-drive rebuild
1 d 9 h 20 min
Chance of ≥1 URE
35.0791%

Rebuild progress and URE probability

Rebuild progress and URE probabilityThe curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.URE probability · 40%0%Elapsed1 d 9 h 20 min35.0791%
  • Chance of at least one read error
The curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.
Layout
RAID 60
Raw capacity
288 TB
Parity / mirror overhead
144 TB
Capacity efficiency
50%
Guaranteed failures tolerated
2
Best-case failures tolerated
8
Read peers
3
Single-drive rebuild assumptions
QuantityEstimate
Replacement writes18 TB
Peer reads54 TB
URE rating (bits per error)1e+15

Questions

Why is the 16-drive RAID 60 design only 50% space efficient?

Each four-drive parity group spends two drive equivalents on protection.

Would a RAID 60 rebuild read all fifteen survivors in this plan?

A one-drive replacement uses the three survivors in the affected parity group in this estimate.

References