Calculate RAID 60 for 16 × 18 TB in four groups
Compare raw and usable space for four four-drive RAID 6 groups, then estimate the peer read volume for a single rebuild.
Try these inputsWorked calculation
- Four equal groups of four drives each put two disk equivalents per group toward parity.
- Data capacity is (16 − 4 × 2) × 18 = 144 TB. Total raw capacity is 288 TB.
- A failed drive involves its own three surviving peers, or 54 TB of full-member reads. Two failures are guaranteed across placements, with up to eight if every group loses two.
Results
- Usable capacity
- 130.97 TiB
- 144 TB
- One-drive rebuild
- 1 d 9 h 20 min
- Chance of ≥1 URE
- 35.0791%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAID 60
- Raw capacity
- 288 TB
- Parity / mirror overhead
- 144 TB
- Capacity efficiency
- 50%
- Guaranteed failures tolerated
- 2
- Best-case failures tolerated
- 8
- Read peers
- 3
| Quantity | Estimate |
|---|---|
| Replacement writes | 18 TB |
| Peer reads | 54 TB |
| URE rating (bits per error) | 1e+15 |
Questions
Why is the 16-drive RAID 60 design only 50% space efficient?
Each four-drive parity group spends two drive equivalents on protection.
Would a RAID 60 rebuild read all fifteen survivors in this plan?
A one-drive replacement uses the three survivors in the affected parity group in this estimate.