RAID, RAIDZ & ZFS Capacity and Rebuild Calculator

Compare RAID and ZFS RAIDZ layouts in TB and TiB. Estimate fault tolerance, single-drive rebuild time and the probability of reading an unrecoverable error.

Inputs

Equal-size drives
Use a measured replacement-drive rate when available.

Calculated in your browser

Results

Usable capacity
87.31 TiB
96 TB
One-drive rebuild
1 d 5 h 37 min 47 s
Chance of ≥1 URE
59.1801%

Rebuild progress and URE probability

Rebuild progress and URE probabilityThe curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.URE probability · 60%0%Elapsed1 d 5 h 37 min 47 s59.1801%
  • Chance of at least one read error
The curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.
Layout
RAIDZ2
Raw capacity
128 TB
Parity / mirror overhead
32 TB
Capacity efficiency
75%
Guaranteed failures tolerated
2
Best-case failures tolerated
2
Read peers
7
Single-drive rebuild assumptions
QuantityEstimate
Replacement writes16 TB
Peer reads112 TB
URE rating (bits per error)1e+15

How the calculator works

Count data-drive equivalents

Mirrors trade capacity for copies. Parity layouts subtract one, two or three drive equivalents per group. Convert decimal TB to binary TiB by multiplying by 10¹² and dividing by 2⁴⁰.

Budget one replacement

Divide replacement bytes by sustained replacement-drive throughput. The RAIDZ estimate scales bytes by used space. Filesystem metadata, block padding, disk size rounding and production I/O can change measured capacity or speed.

Estimate a read error

The model assumes independent reads with one unrecoverable bit error per stated number of bits. It estimates the chance of at least one URE while reading the surviving drives in the affected group. Recovery still depends on which blocks fail and the redundancy remaining.

Questions

Why does RAID 10 show a guaranteed and a best-case failure count?

One failure is tolerable anywhere. More can be tolerated when they are distributed one per mirror pair. Losing both members of one pair loses that pair’s data.

Does the URE percentage measure the probability of losing all array data?

It measures the chance of reading at least one unrecoverable error in the stated model. Multiple-parity layouts can retain enough redundancy to repair some read errors.

References