Estimate RAID 5 rebuild exposure for 5 × 12 TB

Calculate capacity, full-member rebuild duration at 120 MB/s and modeled read-error exposure for one degraded five-drive RAID 5 group.

Try these inputs

Worked calculation

  1. Four data equivalents times 12 TB gives 48 TB usable. One drive equivalent is parity.
  2. Rebuilding a full 12 TB member at 120 MB/s takes (12 × 10¹²) ÷ (120 × 10⁶) = 100,000 seconds, or 1 day 3 hours 46 minutes 40 seconds.
  3. The four peers contribute 48 TB of reads, or 3.84 × 10¹⁴ bits. At one URE per 10¹⁴ bits, the independent model gives about a 97.85% chance of at least one URE.

Inputs

Equal-size drives
Use a measured replacement-drive rate when available.

Calculated in your browser

Results

Usable capacity
43.66 TiB
48 TB
One-drive rebuild
1 d 3 h 46 min 40 s
Chance of ≥1 URE
97.8506%

Rebuild progress and URE probability

Rebuild progress and URE probabilityThe curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.URE probability · 100%0%Elapsed1 d 3 h 46 min 40 s97.8506%
  • Chance of at least one read error
The curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.
Layout
RAID 5
Raw capacity
60 TB
Parity / mirror overhead
12 TB
Capacity efficiency
80%
Guaranteed failures tolerated
1
Best-case failures tolerated
1
Read peers
4
Single-drive rebuild assumptions
QuantityEstimate
Replacement writes12 TB
Peer reads48 TB
URE rating (bits per error)1e+14

Questions

Why are rebuild read bytes four times replacement bytes in RAID 5?

The model reads the corresponding parts of all four surviving drives to reconstruct each missing part. The one replacement receives a single drive’s worth of writes.

Does 120 MB/s mean total throughput over all four RAID 5 peers?

Use the effective throughput of reconstructing the new member. Reading four peers at once does not make that effective rate four times higher.

References