Estimate RAID 5 rebuild exposure for 5 × 12 TB
Calculate capacity, full-member rebuild duration at 120 MB/s and modeled read-error exposure for one degraded five-drive RAID 5 group.
Try these inputsWorked calculation
- Four data equivalents times 12 TB gives 48 TB usable. One drive equivalent is parity.
- Rebuilding a full 12 TB member at 120 MB/s takes (12 × 10¹²) ÷ (120 × 10⁶) = 100,000 seconds, or 1 day 3 hours 46 minutes 40 seconds.
- The four peers contribute 48 TB of reads, or 3.84 × 10¹⁴ bits. At one URE per 10¹⁴ bits, the independent model gives about a 97.85% chance of at least one URE.
Results
- Usable capacity
- 43.66 TiB
- 48 TB
- One-drive rebuild
- 1 d 3 h 46 min 40 s
- Chance of ≥1 URE
- 97.8506%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAID 5
- Raw capacity
- 60 TB
- Parity / mirror overhead
- 12 TB
- Capacity efficiency
- 80%
- Guaranteed failures tolerated
- 1
- Best-case failures tolerated
- 1
- Read peers
- 4
| Quantity | Estimate |
|---|---|
| Replacement writes | 12 TB |
| Peer reads | 48 TB |
| URE rating (bits per error) | 1e+14 |
Questions
Why are rebuild read bytes four times replacement bytes in RAID 5?
The model reads the corresponding parts of all four surviving drives to reconstruct each missing part. The one replacement receives a single drive’s worth of writes.
Does 120 MB/s mean total throughput over all four RAID 5 peers?
Use the effective throughput of reconstructing the new member. Reading four peers at once does not make that effective rate four times higher.