Calculate RAID 50 with twelve drives in two groups
Model 12 × 10 TB as two six-drive RAID 5 groups, then calculate capacity, read volume and which failures can coexist.
Try these inputsWorked calculation
- Split 12 drives into two six-drive groups. Each group reserves one drive equivalent for parity.
- The array has 12 − 2 = 10 data equivalents and 10 × 10 = 100 TB usable.
- A one-drive rebuild reads five peers in the affected group, about 50 TB. Two failures can be tolerated when there is one in each group.
Results
- Usable capacity
- 90.95 TiB
- 100 TB
- One-drive rebuild
- 18 h 31 min 7 s
- Chance of ≥1 URE
- 32.968%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAID 50
- Raw capacity
- 120 TB
- Parity / mirror overhead
- 20 TB
- Capacity efficiency
- 83.33%
- Guaranteed failures tolerated
- 1
- Best-case failures tolerated
- 2
- Read peers
- 5
| Quantity | Estimate |
|---|---|
| Replacement writes | 10 TB |
| Peer reads | 50 TB |
| URE rating (bits per error) | 1e+15 |
Questions
Can the RAID 50 calculator make two groups from eleven drives?
Use equal group widths in this model. Eleven cannot be divided into two equal groups.
Where are the ten data-drive equivalents in this RAID 50?
Each six-drive group contributes five data equivalents. Parity blocks are distributed within the group.