Size a 6 × 20 TB RAID 10 and a mirror replacement
Calculate three mirror pairs, usable TB and the read load from copying one 20 TB survivor to a replacement.
Try these inputsWorked calculation
- Six drives form three equal mirror pairs. Usable capacity is 3 × 20 = 60 TB out of 120 TB raw.
- A single replacement copies from one surviving peer, so expected read and write volume are each 20 TB.
- At 180 MB/s, 20 × 10¹² bytes take about 111,111 seconds, or 30 hours 52 minutes. The layout can survive up to three failures distributed one per pair.
Results
- Usable capacity
- 54.57 TiB
- 60 TB
- One-drive rebuild
- 1 d 6 h 51 min 51 s
- Chance of ≥1 URE
- 14.7856%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAID 10
- Raw capacity
- 120 TB
- Parity / mirror overhead
- 60 TB
- Capacity efficiency
- 50%
- Guaranteed failures tolerated
- 1
- Best-case failures tolerated
- 3
- Read peers
- 1
| Quantity | Estimate |
|---|---|
| Replacement writes | 20 TB |
| Peer reads | 20 TB |
| URE rating (bits per error) | 1e+15 |
Questions
Can RAID 10 with three mirrors continue if two failed disks are in one pair?
That pair would lose both copies. Keeping the other pairs does not preserve the affected data.
How much raw capacity is set aside for mirrored copies in this example?
Three 20 TB copies consume 60 TB, half the raw capacity.