Estimate RAIDZ3 resilver time at 35% utilization

Plan around ten 18 TB drives, triple parity and 120 MB/s replacement speed, with a worked partial-occupancy resilver estimate.

Try these inputs

Worked calculation

  1. Triple parity leaves seven data-drive equivalents, or 7 × 18 = 126 TB of parity-only capacity.
  2. At 35% use, the replacement estimate is 18 × 0.35 = 6.3 TB of writes. Across nine peers, the read estimate is 56.7 TB.
  3. At 120 MB/s, 6.3 TB takes 52,500 seconds, or 14 hours 35 minutes. Actual resilver times depend on block layout and concurrent load.

Inputs

Equal-size drives
Use a measured replacement-drive rate when available.

Calculated in your browser

Results

Usable capacity
114.6 TiB
126 TB
One-drive rebuild
14 h 35 min
Chance of ≥1 URE
36.4663%

Rebuild progress and URE probability

Rebuild progress and URE probabilityThe curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.URE probability · 40%0%Elapsed14 h 35 min36.4663%
  • Chance of at least one read error
The curve estimates the probability of encountering at least one URE as peer bytes are read during one rebuild.
Layout
RAIDZ3
Raw capacity
180 TB
Parity / mirror overhead
54 TB
Capacity efficiency
70%
Guaranteed failures tolerated
3
Best-case failures tolerated
3
Read peers
9
Single-drive rebuild assumptions
QuantityEstimate
Replacement writes6.3 TB
Peer reads56.7 TB
URE rating (bits per error)1e+15

Questions

Why can ZFS utilization affect resilver duration?

ZFS can reconstruct allocated data. The estimator uses a proportional occupancy assumption to approximate the resulting write and read sizes.

What happens to RAIDZ3 capacity when I change used space from 35% to 80%?

The layout’s estimated total capacity stays the same. Its estimated rebuild and peer read volumes increase.