Estimate RAIDZ3 resilver time at 35% utilization
Plan around ten 18 TB drives, triple parity and 120 MB/s replacement speed, with a worked partial-occupancy resilver estimate.
Try these inputsWorked calculation
- Triple parity leaves seven data-drive equivalents, or 7 × 18 = 126 TB of parity-only capacity.
- At 35% use, the replacement estimate is 18 × 0.35 = 6.3 TB of writes. Across nine peers, the read estimate is 56.7 TB.
- At 120 MB/s, 6.3 TB takes 52,500 seconds, or 14 hours 35 minutes. Actual resilver times depend on block layout and concurrent load.
Results
- Usable capacity
- 114.6 TiB
- 126 TB
- One-drive rebuild
- 14 h 35 min
- Chance of ≥1 URE
- 36.4663%
Rebuild progress and URE probability
- Chance of at least one read error
- Layout
- RAIDZ3
- Raw capacity
- 180 TB
- Parity / mirror overhead
- 54 TB
- Capacity efficiency
- 70%
- Guaranteed failures tolerated
- 3
- Best-case failures tolerated
- 3
- Read peers
- 9
| Quantity | Estimate |
|---|---|
| Replacement writes | 6.3 TB |
| Peer reads | 56.7 TB |
| URE rating (bits per error) | 1e+15 |
Questions
Why can ZFS utilization affect resilver duration?
ZFS can reconstruct allocated data. The estimator uses a proportional occupancy assumption to approximate the resulting write and read sizes.
What happens to RAIDZ3 capacity when I change used space from 35% to 80%?
The layout’s estimated total capacity stays the same. Its estimated rebuild and peer read volumes increase.