Worked example

H2 profile in a level canal

A level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Use a positive slope for falling bed, zero for level or a negative value for adverse slope.
Profile controls
m
m
m
m
Use 1 for uniform section velocity.

Hydraulic readout

H2 · Downstream profile

Reach distance: 344.515 m, Critical depth: 0.612191 m, Min. freeboard: 0.45 m

Gradually varied water-surface profileThe direct-step stations are plotted with the channel bed, critical depth and normal depth where defined. The second chart compares depth and available freeboard.REACH DISTANCE344.51 mNORMAL DEPTH—CRITICAL DEPTH0.61219 mMIN. FREEBOARD0.45 mWater surface · downstream →WaterNormal yₙCrit. y꜀Channel depth & freeboardDepthLimitBankAvailable freeboard0.45 m / 0.25 m
  • Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.

Calculation details

Profile type
H2
Bed slope class
Horizontal
Direction
Downstream
Target station
344.515 m
Required freeboard
0.25 m

Direct-step station schedule

StationmDepthmVelocitym/sFroudeFriction slope
01.41.07140.289165.7197e-4
23.6491.3851.0830.293875.888e-4
46.5471.371.09490.298716.0634e-4
68.7071.3551.1070.303686.2462e-4
90.1431.341.11940.30886.437e-4
110.861.3251.13210.314066.6361e-4
130.891.311.1450.319476.844e-4
150.221.2951.15830.325037.0613e-4
168.881.281.17190.330767.2884e-4
186.881.2651.18580.336667.526e-4
204.221.251.20.342747.7747e-4
220.931.2351.21460.3498.0351e-4
237.011.221.22950.355468.308e-4
252.471.2051.24480.362128.5942e-4
267.331.191.26050.368998.8944e-4
281.61.1751.27660.376079.2097e-4
295.31.161.29310.383399.5409e-4
308.421.1451.310.390959.8891e-4
320.991.131.32740.398760.0010255
333.021.1151.34530.406840.0010641
344.511.11.36360.415190.0011047

Interpreting this example

The horizontal class has no finite positive normal-depth line. Friction controls the station increment together with the energy difference.

Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)

Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.

Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet