Worked example
H2 profile in a level canal
A level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
Inputs
Hydraulic readout
H2 · Downstream profile
Reach distance: 344.515 m, Critical depth: 0.612191 m, Min. freeboard: 0.45 m
Input values
- Discharge Q
- 4.5 m³/s
- Bottom width b
- 3 m
- Side slope z (H:1V)
- 0
- Bed slope S₀
- 0
- Manning n
- 0.018
- Control depth y₁
- 1.4 m
- Target depth y₂
- 1.1 m
- Bank depth
- 1.85 m
- Minimum freeboard
- 0.25 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- H2
- Bed slope class
- Horizontal
- Direction
- Downstream
- Target station
- 344.515 m
- Required freeboard
- 0.25 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 1.4 | 1.0714 | 0.28916 | 5.7197e-4 |
| 23.649 | 1.385 | 1.083 | 0.29387 | 5.888e-4 |
| 46.547 | 1.37 | 1.0949 | 0.29871 | 6.0634e-4 |
| 68.707 | 1.355 | 1.107 | 0.30368 | 6.2462e-4 |
| 90.143 | 1.34 | 1.1194 | 0.3088 | 6.437e-4 |
| 110.86 | 1.325 | 1.1321 | 0.31406 | 6.6361e-4 |
| 130.89 | 1.31 | 1.145 | 0.31947 | 6.844e-4 |
| 150.22 | 1.295 | 1.1583 | 0.32503 | 7.0613e-4 |
| 168.88 | 1.28 | 1.1719 | 0.33076 | 7.2884e-4 |
| 186.88 | 1.265 | 1.1858 | 0.33666 | 7.526e-4 |
| 204.22 | 1.25 | 1.2 | 0.34274 | 7.7747e-4 |
| 220.93 | 1.235 | 1.2146 | 0.349 | 8.0351e-4 |
| 237.01 | 1.22 | 1.2295 | 0.35546 | 8.308e-4 |
| 252.47 | 1.205 | 1.2448 | 0.36212 | 8.5942e-4 |
| 267.33 | 1.19 | 1.2605 | 0.36899 | 8.8944e-4 |
| 281.6 | 1.175 | 1.2766 | 0.37607 | 9.2097e-4 |
| 295.3 | 1.16 | 1.2931 | 0.38339 | 9.5409e-4 |
| 308.42 | 1.145 | 1.31 | 0.39095 | 9.8891e-4 |
| 320.99 | 1.13 | 1.3274 | 0.39876 | 0.0010255 |
| 333.02 | 1.115 | 1.3453 | 0.40684 | 0.0010641 |
| 344.51 | 1.1 | 1.3636 | 0.41519 | 0.0011047 |
Interpreting this example
The horizontal class has no finite positive normal-depth line. Friction controls the station increment together with the energy difference.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M2 drawdown to a drop structureA mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.